Abstract: the electromagnetic flow meter scale advantages and shortcomings of the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation.
On the structure, electromagnetic flowmeter consists of two parts, electromagnetic flow sensor and converter.
Sensor installed on the industrial process piping, its role is to flow into the pipe of liquid volume flow values into a linear change of induced electric potential signal, and through the transmission line.
More flow meter manufacturers choose model price quote you are welcome to inquire, here is the electromagnetic flowmeter scale advantages and shortcomings of the article details.
On the structure, electromagnetic flowmeter consists of two parts, electromagnetic flow sensor and converter.
Sensor installed on the industrial process piping, its role is to flow into the pipe of liquid volume flow values into a linear change of induced electric potential signal, and through the transmission line will be sending the signal converter.
Converter is installed in place not far away from the sensor, it will flow from sensor signal amplifier, translates into electrical signal proportional to the standard traffic signal output, for display, accumulation and adjustment control.
The main advantage of the electromagnetic flowmeter is as follows: 1)
Electromagnetic flowmeter sensor structure is simple, the measuring tube has no moving parts, no obstacles to fluid flow throttling components.
So when the fluid flow through timing does not cause any additional pressure loss, flow meter is running in one of the flowmeters zui low energy consumption.
2)
Measurable smudges medium, corrosive medium and clouding the liquid-solid two phase flow of traffic.
This is due to internal unimpeded flow meter tube parts, and the measurement of body contact is sounding pipe lining and electrode, the materials can choose according to the nature of the current body.
For example, made from poly three fluoride or ptfe lining, can measure all kinds of acid, alkali, salt and other corrosive medium.
Adopt wear-resisting rubber lining, is especially suitable for measuring with solid particle slurry, water slurry, wear a large liquid-solid two phase flow and various liquid with fiber and pulp suspension.
3)
Electromagnetic flowmeter is a kind of volume flow measuring instrument, in the process of measurement, it is not affected by the temperature of the measured medium, viscosity and density with conductivity (
In a certain range),
The influence of.
Therefore, electromagnetic flowmeter only after water calibration, it can used to measure the conductivity of liquid flow.
4)
The output of the electromagnetic flowmeter is proportional to the average flow velocity of the measured medium only, and with the flow state of symmetrical distribution (
Laminar or turbulent)
Has nothing to do.
So the electromagnetic flowmeter range very wide range, the measurement range can be up to 100:1, some even up to 1000:1 working flow range.
5)
Electromagnetic flowmeter (
)
No mechanical inertia, responsive, can measure the instantaneous pulse flow, also can measure the rate of flow of positive and negative two directions.
6)
Industrial use very wide range of the calibre of the electromagnetic flowmeter, from a few millimeters to a few meters, and the domestic existing diameter up to 3 m's real flow calibration equipment, which laid a foundation for the application and development of electromagnetic flow meter.
Electromagnetic flowmeter is still the main deficiencies are as follows.
1)
Cannot be used to measure the gas, steam, and contains a lot of gas liquid.
2)
Cannot be used to measure the low conductivity of liquid medium, such as the petroleum products or organic solvent such as medium, the electromagnetic flowmeter is powerless.
3)
Ordinary electromagnetic flow meter used in industry due to the measuring tube lined with the limitation of materials and electrical insulation materials, can not be used in measuring high temperature medium;
If without special treatment, also cannot be used for the measurement of low temperature medium, in order to prevent the measuring tube outer condensation (
Frost)
Destruction of insulation.
4)
The influence of electromagnetic interference electromagnetic flowmeter are susceptible to the outside world.
Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd's products comply fully with all compatible producing regulations.
Beijing Sincerity Automatic Equipment Co., Ltd’s goal is to achieve customer satisfaction through excellence in design, supply chain management, manufacturing and repair solutions.
The same determination is critical for business owners. The journey in mass flow meter business is both a challenging and rewarding experience.
Beijing Sincerity Automatic Equipment Co., Ltd is an expert in manufacturing a wide range of . We also have high quality fork density meter manufacturer and many others. Visit to know more.