Abstract: the installation of electromagnetic
flow meter scale classification structure selection information produced by excellent flow meter, flow meter manufacturer to offer you the quotation.
Electromagnetic flowmeter installation electromagnetic flow correctly installed to the normal operation of the electromagnetic flowmeter is extremely important, it mainly introduces the installation of electromagnetic flow sensor and converter.
Electromagnetic flowmeter sensor electromagnetic flowmeter sensor installation should pay attention to in installation.
More flow meter manufacturers choose model price quote you are welcome to inquire, here is the installation of the electromagnetic flowmeter scale classification structure to choose the article details.
Electromagnetic flowmeter installation electromagnetic flow correctly installed to the normal operation of the electromagnetic flowmeter is extremely important, it mainly introduces the installation of electromagnetic flow sensor and converter.
Electromagnetic flowmeter sensor installation of electromagnetic flowmeter sensor installation should pay attention to the following questions: (
1)
Installation place of ordinary electromagnetic flow sensor shell protection grade reaches IP65 (
GB4208 rules of dustproof splash water level)
To the requirements of the installation site is: 1)
When measuring mixed phase flow, should choose the place that does not cause phase separation;
2)
Choose the place that there will be no negative pressure measuring tube;
3)
Avoid installation near high voltage equipment such as motors, transformers, lest cause electromagnetic interference;
4)
Avoid installed around the place that has a strong corrosive gas;
5)
The environment temperature should be in commonly -
25 ~ 60 ℃ range, as far as possible, avoid direct sunlight.
6)
Installed in no vibration or the place of small vibration.
If the vibration is too large, should in the sensor before and after the pipe plus fixed support.
7)
Environmental relative humidity shall generally be in the range of 10% ~ 90%;
8)
Avoid installed in straight tube can be rain or submerged by water.
If the sensor is IP67 protection grade (
Dust-proof and flooding level)
Or IP68 (
Dust-proof and diving level)
Zui, after two can not make the request.
(
2)
Straight pipe length of electromagnetic flowmeter requirement for straight pipe length before table is low.
Typically, for 90 & deg;
Elbow, tee, tee, reducer, and fully open the valve and flow resistance and attachments from the sensor electrode shaft centerline (
Not sensor import face)
Should be a 3 -
5 d straight pipe length;
For different opening of the valve and will have 10 d straight pipe length;
Commonly after sensor should have a 2 d straight pipe length.
When the valve is not fully open, if the direction of the valve closure and sensor electrode axis 45 & deg;
Installation, can greatly reduce the additional error.
(
3)
Electromagnetic flow sensor installation position and direction of flow can be horizontal, vertical or inclined installation.
When mounted horizontally, the sensor electrode shaft must be placed.
This will prevent the entrained air bubbles due to fluid and the electrode insulated short time;
Also can prevent electrode is covered by fluid in the sediments.
Should not install the sensor in zui high, in order to prevent gas buildup, installed in a piping zui high, as the poor installation location, should be avoided.
Vertical installation, should make the direction of flow upward, this makes no flow or flow is very small, the entrainment of fluid in the heavier solid particles sinking, and lighter fatty substances rising leave sensor electrode area.
Measure the mud, the liquid-solid two phase flow such as pulp, vertical installation can avoid solid phase precipitation and sensor lining uneven wear.
The pipeline under always exit, for bad installation location, should be avoided.
Back pressure sensor installation area should be, sensor export direct emptying of the measuring tube liquid filled tube, for bad installation location, should be avoided.
In order to prevent to produce negative pressure sensor, the sensor should be mounted at the rear of the pump, and should not be installed in the front of the pump.
(
4)
Install bypass pipe for liquid flow static check and adjust the zero point, when the medium and small diameter should be as far as possible to install bypass pipe.
Should be considered when measuring sediment containing fluid, easy to clean the sensor installation method.
(
5)
Grounding in order to make the measuring accuracy and electrode current corrosion will not occur, electromagnetic flow sensor must be separate grounding, and makes the sensor and the fluid around at the same potential.
Separation type electromagnetic flow meter, grounding in principle should be in sensor, converter grounding should be in the same place, in most cases, the sensor of built-in reference electrode or metal tubes can ensure potential balance.
Therefore, can be built in ground reference electrode and metal pipe flow, the sensor of the ground lug connected to ground wire.
If the sensor is installed on the pipeline with cathodic corrosion protection, in addition to the sensor and grounding ring together, with a thick copper wire around the sensor jumper on two flanges in the pipeline, the isolation between the cathodic protection current and sensors.
For non grounded metal pipe, application of thick copper wire connection, ensure the flange to flange and the flange is connected to the sensor.
For the lining of conductive plastic tube or pipe, if there is no reference electrode or because of the existence of potential balance current will flow through the grounding ring.
According to the excitation type classification 1)
Dc excitation type of this kind of electromagnetic flowmeter few in number, only used for measuring the liquid metal flow, such as temperature of mercury and the high temperature liquid sodium, potassium, etc.
Technology is a foundational component of today's fast-paced business environment. Beijing Sincerity Automatic Equipment Co., Ltd who are digital natives are especially equipped to harness technology's power to establish, promote and grow our businesses.
We want to continue to organize Sincerity to make it more efficient and profitable so that both, our clients and our employees can get more out of their time.
The lower cost of mass flow meter, compared to other product, and Beijing Sincerity Automatic Equipment Co., Ltd’s services provide may well suit the needs for customers.