loading

Sincerity Group | Coriolis flow meter manufacturers| 


Design of the control system of water meter scale test and research

Abstract: the design of the control system of water meter scale test and research on information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Abstract: in the past the main water flowmeter calibration system using manual and half a manual way to control, its defect is low precision, big flow fluctuation, is calibrating table diameter range is small, do not have a high level of automation, low efficiency of inspection table. In this paper, based on water flow meter. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the design of the control system of water meter scale test and research articles for details. Past water flowmeter calibration system is mainly controlled by manual and half a manual way, its defect is low precision, big flow fluctuation, is calibrating table diameter range is small, do not have a high level of automation, low efficiency of inspection table. In this paper, according to the requirements of the water flow meter calibration process, combining with the working conditions of the original verification system, on the basis of oil chemical automatic control system design specifications, water meter calibration control system is designed. The control system with computer and the inverter as the core, has realized the automatic control in the true sense, reduce the labor intensity of the workers, improve the labor efficiency, full range of water meter calibration tasks can be completed, save the test cost, ensure the normal operation of production. 1, the system of the system core, collecting and distributing control manner, the host machine adopts high quality research China IPC industrial-grade computer and 21 & Prime; Large screen monitor, mainly to undertake system administration tasks, such as a variety of data and signal detection, storage, analysis and processing; Various graphics, images, curve according to read; To check the monitoring events, fault alarm, record, certificate check printing, etc. The next bit machine adopts Japanese OMRON company produces the programmable controller, industrial system of the implementation of all control tasks, the execution of the actions, the output of the control mode, are carried out by the lower machine PLC, as the control center, it with extremely high frequency continuously all sorts of data and information exchange with PC to realize system control. The whole test system is divided into system control part and the field test execution part, through the cable connection between the two parts. 1 system control part of the system control part is divided into five parts, as shown in figure 1. ( 1) The center of the whole system console ( System control cabinet) It includes a research China IPC - 586 industrial computer, a 21 & Prime; Large screen monitor, a DPK - 8400 paper printer, a set of OMRON200H programmable controller PLC, 11 sets of distributor, 6 sets of switch power supply, 10 air switch, 3 ac contactor, an alarm, a signal processor, a set of four road isolated relay, a frequency adjust potentiometer and 30 buttons and indicator lights. ( 2) Checked table output power and signal wiring and no - table data operation counters this ark is propped in test site, the canal on the operation panel, digital display tube with film, ready buttons and lights, abrupt stop button, the power switch, pluggable control button and the connection cable. ( 3) Solenoid valve in ark cabinet is equipped with 8 sets of solenoid valve and four relay, including four sets of solenoid valve control of four standard tank bottom valve switch, two two commutator of the reversing solenoid valve control. This 6 solenoid valve can not only realize the automatic control by computer and can realize manual control via a button control on the ark, every button with signs in order to avoid wrong operation. The other two, electromagnetic valve, a spare a control switch DG200 pipe pneumatic water drain valve. Four relays offer PC bottom valve switch state. ( 4) Frequency converter cabinet this ark is propped up by canal of 175 kw inverter, anti-interference reactor and intermediate relay, air switch, ac contactor and some other electrical components, its main function is used to implement the motor start and stop of frequency conversion. Inverter starting and stopping is divided into automatic and manual two work modes: when the inverter work automatically, automatic selection by the upper machine to start the motor, by the machine according to the test when the flow of set point frequency control signal to frequency converter. When need to manually start the inverter, the on site & other; Manual/automatic & throughout; Control button to manual work mode, can be realized by adjusting the frequency converter on frequency adjust potentiometer, and the frequency of manual adjustment can be realized by the transformation of the system control ark button field and long-distance operation control room. Variable frequency ark also equipped with vacuum pump water tank liquid level relay control. ( 5) Electrical control operation counters the ark from all around the power distribution cabinet group into operation, its main function is to pump room inside the motor power supply and on the operation panel to realize manual frequency and power frequency startup; Mounted on the operation panel & other; Manual/automatic & throughout; Switch,, stop the pump button 15, state light is 26. 2 in-situ test execution parts field test execution by standard table, inspection table, frequency converter, the standard of cans, commutator, pump group.

At the same time, as the recent research of Sincerity shows, the benefits of improved productivity and firm performance can make implementing basic management practices worth it.

Through our culture, our drive and the expertise of each individual employee, Beijing Sincerity Automatic Equipment Co., Ltd is uniquely positioned to provide best-in-class services to a global customer base.

The first machine to produce tuning fork liquid density meter, the fork density meter manufacturer mass flow meter was invented in rosemount coriolis mass flow meter in endress hauser coriolis mass flow meter by digital fork density meter and was subsequently improved.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect