loading

Sincerity Group | Coriolis flow meter manufacturers| 

Rotameter scale pointer fluctuations too big how to eliminate

by:Sincerity Group     2020-11-11
Abstract: the rotameter scale pointer fluctuations too big how to eliminate the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Metal tube rotameter consists of cone tube, float, indicator and converter. Fluid flow into the taper pipe float up, the lift M is balanced with the gravity G, the displacement of the float through the magnetic steel is passed to the indicator on the instruction flow or is converted to the corresponding by the converter. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a rotameter scale pointer fluctuations too big how to eliminate the article details. Metal tube rotameter consists of cone tube, float, indicator and converter. Fluid flow into the taper pipe float up, the lift M is balanced with the gravity G, the displacement of the float through the magnetic steel is passed to the indicator on the instruction flow or is converted to the corresponding electrical signals by the converter ( 4 - two wire 20 ma, three-wire system 0 - 10 mA, 4 - four wire system 0 - 20 mA 20mA) As DDZ - Ⅱ,DDZ - Ⅲ type electric unit combination instrument, I series, EK series instrument match, long-distance traffic can also be used with the computer network, according to records, and adjust, integrating and controlling. The problems usually have the following: 1, the system opens a pointer property of reasons: the medium contains impurities, make the rotor stuck; System working pressure is too small, the instrument is not normal work,. Solution: : removal; Increasing magnetic filter, system working pressure. 2, the cause of pointer header to don't reply: medium containing impurities, make the rotor stuck; Inappropriate instrument selection, selects the meter is too small. Solution: removal, increase magnetic filter; 3, the cause of pointer fluctuation is too big, can't accurate readings, causes: system working pressure is not stable; Medium existence of pulsating flow or dual phase flow phenomenon; Instrument import and export of big diameter change or increase the pressure loss caused by pressure changes. Solution: check their systems; Eliminate the pulsating flow and two phase flow. To reduce the pressure loss. 4, the cause of pointer not back to zero: due to the fluctuation of instrument pointer displacement; Due to the fluctuation impacts, and make the measuring tube bending deformation of parts. Solution: a pointer to the small screws to unscrew the pointer recovery to not working state; Advice to repair or replacement. 5, far eastone inaccurate reason: the environment temperature is beyond work requirements; Transmitter drift. Solution: use as required; Properly adjusting screw to adjust potentiometer in the transmitter or to return to normal. 6, the normal of fluid flow, according to total counter words without increasing: check the power cord, fuse, function selection switch and signal lines have break or poor contact; Check the internal display, print, contact elements such as presence of poor contact; Check the detection coil; ; Check the internal fault of sensor and the 1 - 3 items were confirmed normal or has ruled out fault, fault phenomena, but there are still to show that the fault sensors inside circulation channel, can check whether the impeller touch sensor inside, presence of foreign bodies stuck, shaft and bearing have sundry jam or fracture phenomenon. Solution: use ohmmeter screening point of failure; Fault check printing plate can be used to replace & other; Alternate version & throughout; Method, for fault board again careful check; Completes the detection coil in the sensor location mark in the table body, unscrew the detection head, use iron under the detection head moving fast, if the counter does not increase, should check whether there is any break on the coil and the solder joint sealing off; Remove foreign bodies, and clean or replace the damaged parts, after his recovery, blowing or hand toggle impeller should be frictionless, should check again after changing the spare parts such as bearings, new instrument coefficient are obtained. 7, not reduce flow operation, but flow showed declining: filter blockage, if the filter differential pressure increases, that stuff has been blocked; Valve on the flow sensor section appears loose valve core, valve opening automatically reduce; Sensor impeller by sundry obstacles or bearing clearance to enter foreign body, slow resistance increases with the reduction. Solution: remove the filter; From the effective judgment, whether the valve handwheel adjustment confirm again after repair or replacement; Unload sensor to clear, if necessary, check again. 8, fluid flow, flow display is not zero, or unstable display values: shielding grounding, a transmission line interference signals mixed with display input; Pipeline vibration, the impeller jitter, error signal; Cut-off valve closed lax caused by leakage, in fact, the instrument shows leakage; Display the internal circuit board or electronic components between metamorphic damage, interference. Solution: check the shield, display terminals are good grounding; Before and after reinforcement line, or in the sensor support to help them avoid vibration; Repair or replace the valve; Take & other; Short-circuit method & throughout; Or item by item, check them one by one, judge the interference source, find out the point of failure. 9, display and experience value for evaluating value significant difference: sensor circulation channel internal fault, such as fluid corrosion, wear serious, sundry obstacles make impeller rotation disorder, instrument coefficient of leaf is impacted by the corrosion or change, at the top of deformation, affect the normal cutting lines, detecting coil output signal disorders, instrument coefficient changes: the fluid temperature is too high or too low, shaft and bearing expansion or contraction, too much clearance changes bring an aberration of the impeller rotating instrument coefficient change.
The use of tuning fork liquid density meter mass flow meter is a great trend in today's world. What you should know is that it has become a very important part of business today.
Beijing Sincerity Automatic Equipment Co., Ltd assures you that you will be satisfied with its results and humbly request you to try this. We are hoping for a better business deal with you.
Using high-quality materials to produce mass flow meter is one of the most important part during manufacturing.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: