Abstract: DK800 - 6 rotameter scale application in hyperbaric oxygen chamber and maintenance information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. In the hyperbaric oxygen therapy, put the body in hyperbaric oxygen chamber high pressure environment, let patients breathing pure oxygen and environmental pressure, the air pressure cabin the two important link of hyperbaric oxygen therapy. The oxygen in high pressure environment is effective to patients with hyperbaric oxygen treatment. More flow meter manufacturers choose model price quote you are welcome to inquire, here is DK800 - 6 rotameter scale application in hyperbaric oxygen chamber and repair the article details. In the hyperbaric oxygen therapy, put the body in hyperbaric oxygen chamber high pressure environment, let patients breathing pure oxygen and environmental pressure, the air pressure cabin the two important link of hyperbaric oxygen therapy. And patients in the high pressure oxygen environment was valid or not, is the key link in hyperbaric oxygen therapy. DK800 - 6 application of rotameter, from the objective to ensure the visual observation whether patients with oxygen effectively. For lung type oxygen ( On demand of oxygen) And continuous for two different ways of oxygen, oxygen DK800 - 6 rotameter respectively played a qualitative and quantitative indicator of the clinical application of how to quickly and easily for repair also worth exploring. 1 DK800 - 6 rotor flowmeter with hyperbaric oxygen treatment of clinical application of enlargement of the application of innovation and oxygen terminal, oxygen supply methods, once a single lung type oxygen develop lung type oxygen and oxygen to continuous type two kinds. Therefore, DK800 - 6 rotameter in clinical application of also has a new usage. One is the conventional usage, namely DK800 - 6 rotor flowmeter is applied in lung type oxygen. This usage can be convenient, intuitive qualitative observation on the flowmeter, the main observation effective oxygen patients and each time the size of the instantaneous flow oxygen condition, if the instantaneous flow, little or no shows that there was no wear masks, face with a mask of leak contact part, exercise class member through such observation to guide in patients in a timely manner to correct adverse conditions, guarantee the effective oxygen. Second is to expand the usage, namely DK800 - 6 rotor continuous type oxygen flow meter application. Flowmeter is when the switch is used for flow control, can adjust the flow rate of the size of the quantitative, fuck class member by observing the oxygen cabin terminal balloon to adjust the size of the oxygen flow rate, the size of the flow meter of this usage can guarantee effective oxygen, but still have to pay close attention to patients with oxygen terminal air tightness, lest cause oxygen cabin leakage oxygen concentration is on the high side. DK800 - 6 rotameter this two USES to solve the problem of all kinds of the patient's oxygen demand and effective oxygen, benefit more patients. 2 DK800 - 6 rotameter DK800 - common faults and maintenance Six little faults in the rotor flow meter in normal usage, because there is no operation, the usage of flowmeter in static use; And expand the usage in flowmeter is a kind of dynamic use, every time in the process of treatment, the patients began to oxygen and intermediate stop oxygen ( Have a rest) And the size of the oxygen flow rate adjustment, will be flow meter, flowmeter in this dynamic use of easily out of order, now in its common faults and maintenance summarized as follows: 2. 1 DK800 - 6 rotameter close this failure phenomenon is not tight (flowmeter knob The flowmeter knob clockwise to tight) , flow meter glass tube steel ball ( Rotor) Is still floating, naked eye can see a relatively small flow indicator. The root cause of this failure is caused by flow meter with seals conical adjustment screw on the back and front, the central item with small cylinder neck running-in surface joint adverse regulation of the interface. Because the joint surface is rigid joint, when the switch knob hard improper grinding and groove are easy to cause surface damage caused by closed tight, not available when maintenance zero sand paper respectively in the adjusting screw of the conical joint face and adjustment of the seat of the round neck cylinder hole faying surface polishing, using the method of rotating generally 30 ~ 50 turns can make the joint of contact face is good, fix the breakdown. The method about 3 ~ 4 times to repair, once adjust seat of a small cylinder smooth neck, can no longer repair using the method of sand paper burnish. In practice, we discuss the repair again by using the combined method of firm soft and the effect is good, the particular way is: based on blood pressure cuff rubber tube ( Outer diameter of 8 mm, inner diameter 4 mm) , 5 mm cut section, this section rubber tube can be appropriately placed in the adjustment with adjustment screw between the rigid fixed casing, the casing is a camp inside about 3 mm, can make the rubber tube tightly set, candy, rubber tube protruding part about 2 mm, outside under the fastening nut and adjust seat tightly together, this section of the rubber tube not only has the effect of rubber gasket seal, but also makes the original adjustment with adjustment screw rigid joint into firm soft joint, which shut down is not tight to get a thorough solution, this innovative maintenance can improve the performance of the switch on the meter, light switch, and can no longer appear flowmeter shut down for a long time not fault, until the rubber tube to replace aging deformation. 2. 2 DK800 - 6 rotor flowmeter can't open this failure phenomenon is flowmeter open no flow indicator ( Flow meter didn't float glass tube rotor) There are two, the cause for the failure. One is the flowmeter knob outer nut should be enough (but Loose) , make the rotor flowmeter will follow the adjustment screw rotation together, so you can't open flow, this kind of situation is often accompanied by a knob zui bigger disappear with closed point, both knob turn left turn right turn does not end, sometimes nut place outside leakage occurs, using a wrench to tighten nut can eliminate the problem.
Finding a reliable solution for the mass flow meter low flow turbine flow meter not only supports operation of the entire system but also enhance the beauty of your workplace.
Exceed customers' expectations in the procedures of manufacturing mass flow meter.
Basically, you cannot have a digital fork density meter without having the right mass flow meter. Since you are going to use it regularly, be sure to invest in one that has a high quality.
The lower cost of mass flow meter, compared to other product, and Beijing Sincerity Automatic Equipment Co., Ltd’s services provide may well suit the needs for customers.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com