loading

Sincerity Group | Coriolis flow meter manufacturers| 


Analysis and solutions of how to solve the oil leakage phenomenon of pressure calibrator

Abstract: The analysis and solution information on how to solve the oil leakage phenomenon of the pressure calibrator is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. In the use of the pressure calibrator, one of the primary requirements for its function is that the sealing performance is good, and each transmission channel must not have oil leakage. If there is oil leakage, it cannot be used and must be repaired. Common oil leaks in pressure calibrators and usually repaired. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the analysis and solution article details of how to solve the oil leakage phenomenon of the pressure calibrator. In the use of the pressure calibrator, one of the primary requirements for its function is that the sealing performance is good, and each transmission channel must not have oil leakage. If there is oil leakage, it cannot be used and must be repaired. The common oil leakage parts of the pressure calibrator and the usual repair methods are introduced for reference: 1. The connecting parts at the joint of the pressure calibrator are not well fastened, so oil seeps. The upper and lower nuts at the joint should be twisted in opposite directions to each other. Just do it. 2. The pressure gauge is not tightened to connect with the gasket in the joint, so the pressure gauge should be tightened again if the oil seeps, or the gasket should be thickened so that it can connect with the top plane of the pressure gauge joint. When the thread cooperation of the external joint is not good and oil leakage occurs, some of them are the deformation and damage of the tooth pattern of the external joint of the pressure gauge. You can use a suitable thread to twist it, otherwise you can wrap a few strands of fine yarn on the external joint of the pressure gauge. Or wrap it with PTFE raw material tape, and then tighten it. 3. The sealing gasket between the connecting parts of the pressure calibrator is aging and damaged, so oil leaks, some bxs should be disassembled and replaced with a new sealing gasket. 4. The closing valve is not tightened, or the thimble rod has burrs, so oil seeps. If the above conditions exist, if further closing of the valve is ineffective, the finish of the thimble rod should be repaired. A simple repair method, after applying the grinding sand with fine cotton yarn, wrapping it in the thimble rod*, grinding and polishing with continuous changes, can usually be corrected. 5. Oil leakage at the screw. Such conditions are mostly due to the wear of the rubber sealing cup at the top of the screw rod, and a new oil-resistant rubber cup should be replaced. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'How to solve the analysis and solution of the oil leakage phenomenon of the pressure calibrator'

Building a brand as Sincerity from the very start is simple so long as you keep 'the three C's' in mind: clarity, consistency and constancy.

Beijing Sincerity Automatic Equipment Co., Ltd is one of China's leading providers of state-of-the-art . For decades, we've served numerous residential, commercial, and industrial clients. To contact us for a free quote for your home or business please visit Sincerity Flow Meter.

have three basic components.

Deeper connections between Sincerity and mass flow meterare made when you go beyond the white lights of a corporate space.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect