Abstract: the matters needing attention when installing intelligent vortex flow meter scale information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. 【 Introduction 】 Vortex street flowmeter measuring gas or liquid flow rate in all kinds of industries widely used. Itself has a number of subclasses flowmeter no advantages. In the process of installation of vortex flowmeter is very important. The correct installation of vortex flowmeters. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the matters needing attention when installing intelligent vortex flow meter scale article details. 【 Introduction 】 Vortex street flowmeter measuring gas or liquid flow rate in all kinds of industries widely used. Itself has a number of subclasses flowmeter no advantages. In the process of installation of vortex flowmeter is very important. The correct installation of vortex flowmeters can have the effect of get twice the result with half the effort. In actual measurement using vortex flowmeter has the incomparable measuring flexibility, high reliability, excellent performance, durability and low cost, etc. Vortex flowmeter can be directly installed on the pipeline, any instrument in the vertical and horizontal Angle can work normally. With flowmeter signal converter body into 270 & deg; Rotation Angle. Vertical pipe installation in & other; Bulk & throughout; Works for the good, liquid filled piping ( Flow direction must be from bottom to top) 。 Installed in the vortex flow timing if not when can lead to a vortex flow cannot work normally, or show the problems such as inaccurate measurements. Let's say how to correct installation of vortex flowmeter. Vortex street flowmeter installation considerations are as follows: 1, the connection of the pipe flange dimensions must be the same as the instrument of nominal size and flange hole should be smooth, zui is a butt welding flange; 2, flow meter must be installed in no obstacle on the straight pipe; 3, installation, be careful not to make the fluid produces steam when flange sealing ring; 4, the import and export of flowmeter can not installed in the pump, pump often produce the oscillation fluid, can affect the bluff body vortex flowmeter produce the vibration of the pipeline; 5, if flow meter installed in the pump export, will suffer severe flow pulsation, cause the damage of the sensor; 6, flow meter installed near the vibration dampers can cause the same damage; 7, instrument four times the pipe diameter upstream and 2 pipe diameter downstream within the scope of the pipe surface should be no dust, sand holes, cracks, protruding objects and other surface uneven; 8, should be considered when installing the instrument instrument maintenance is convenient. If replacing sensor can't interrupt fluid, before the installation of flow meter shall be installed isolation branch; 9, zui install bypass pipe, in order to make repairs to remove the entire instrument. 10, when measuring the liquid, it is suggested that the flow meter installed in the upstream of regulating valve, so that can guarantee the full package and enough back pressure to avoid and flash vaporization of liquid cavitation; 11, when measuring gas, there are several kinds of installations, for zui big measurable range, suggest the downstream of the flow meter installed on the regulator 10 to 30 times the pipe diameter or more, so that can ensure zui large flow velocity, so as to make the sensor produces zui effective signal; If, flow stability, flow meter can be installed in the upstream of regulating valve, because of the regulating valve upstream pressure fluctuations tend to be small; 13, when measuring the steam, it is suggested that the flow meter installed downstream of the regulating valve 10 to 30 pipe diameter distance, so particularly effective to measure the saturated steam, to ensure the flow condensation zui small amount. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
The use of vortex flow meter manufacturer mass flow meter is a great trend in today's world. What you should know is that it has become a very important part of business today.
Have you been looking for a good mass flow meter u shape coriolis mass flow meter provider? If so, we suggest that you check out Beijing Sincerity Automatic Equipment Co., Ltd at Sincerity Flow Meter.
Beijing Sincerity Automatic Equipment Co., Ltd has developed a unique technology with many applications including v shape coriolis mass flow meter.
We persevere in keeping the customers pleasant and supporting them with mass flow meter at a reasonable price.
The risk of rosemount coriolis mass flow meter is reduced by digital fork density meter with the consumption of .
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com