Abstract: the voltage compensation is suitable for those cases the measurement of steam? Information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Steam divided into saturated steam and superheated steam, in general, manufacturers will give saturated vortex flowmeter, superheated steam mass flow rate range table for user selection, in order to determine the diameter size. For superheated steam to temperature and pressure compensation, for real. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a voltage compensation is suitable for those cases the measurement of steam? The article details. Steam divided into saturated steam and superheated steam, in general, manufacturers will give saturated vortex flowmeter, superheated steam mass flow rate range table for user selection, in order to determine the diameter size. For superheated steam to compensate the temperature and pressure, in the true sense of saturated steam temperature or pressure compensation, according to temperature and pressure when measuring density check table to ensure the required quality traffic. Due to the condition changes, when actual measurements of saturated steam and superheated steam may deviate from the original state of design, makes the usually by steam temperature and pressure to calculate its density change, the relationship between affect measurement accuracy. Wet saturated steam after the vortex flow meter installed in the pressure reducing valve, wet saturated steam suddenly significantly reduced pressure, fluid of adiabatic expansion, the droplets evaporate part, absorb heat of vaporization from the liquid and vapor phases at the same time, the lower the temperature of liquid, if the temperature is lower much or evaporates before humidity is higher, can make the temperature down to rapid and new pressure of the saturated temperature, establish a new equilibrium, steam is still the saturated steam at this moment, if the pressure to reduce a lot or evaporates before humidity is low, due to water evaporation and the lower the temperature is still higher than new pressure after the corresponding saturation temperature, the steam into superheated steam. In superheated steam flow computing devices according to the density of superheated steam temperature and pressure look-up table to calculate the mass flow rate, but when the superheated steam after long distance transmission, or due to improper measures of pipeline insulation, often because of the temperature to reduce the heat loss from overheating state into the critical saturation state, and even some steam condense into droplets by a phase change, then become wet saturated steam ( Supersaturated steam) 。 The output of the vortex flowmeter with only through the measuring tube is directly proportional to the fluid velocity, when moisture saturated steam, water droplets on the influence of vortex street flowmeter output negligible, so you can think of vortex street flowmeter output entirely by various steam dry wet full part ( Saturated part) Caused, and the density of dry part according to pressure or temperature compensation pinpointed. Steam metering part if the two sides agreed by steam when clearing fees, condensed water not to collect fees, the phase transition to measure the impact of small, can be ignored. If also in accordance with the steam condensed water fee, the vortex street flowmeter measurement results on the low side. After the occurrence of the evaporation, the former had no effect on compensation, just dry part of the increase in steam, dry degree increases accordingly, the latter is wet saturated steam into superheated steam, then the impact on the meter points the following three conditions: ( 1) When the design has been given the steam into overheating, or difficult to determine what is the status, or sometimes is overheating sometimes is saturated state, so the temperature pressure compensation, the above phase change not influence the result of the measurement. ( 2) Design according to the saturated steam, and USES the pressure compensation, the above phase transition will lead to smaller error, namely the superheated steam temperature with saturated steam temperature difference caused by density difference of corresponding compensation error. ( 3) Design according to the saturated steam, but USES the temperature compensation, the superheated steam temperature as saturation temperature check density table, generally can cause larger error. Solve the above problem has the following three ways: ( 1) Will always steam flow meter installed in front of the pressure reducing valve, due to the steam without decompression, there is no phase change problem, so install before the pressure reducing valve, flow meter according to the compensation method for saturated steam processing, can guarantee the measurement accuracy. ( 2) If the flowmeter can only be installed behind the pressure reducing valve, can be added 1 pressure transmitter, temperature pressure compensation. ( 3) If better stability of the pressure reducing valve, flow meter can be upstream pressure value as a constant value is set to display instrument, temperature and pressure compensation. Voltage compensation installation diagram: vortex flowmeter samples show: after-sales and warranty qin instrument ( Shanghai) Supply all of the products: all product quality assurance 2 years; Provide free consultation, guide the installation and debugging and other services; Negotiation matters such as the door to guide installation, commissioning, charge reasonable travel expenses; Large amount of free door-to-door to guide installation, commissioning; Service tenet: no matter how long it products use, as long as you find us, we will solve all problems for you, until satisfied. Believe that we are engaged in the flow meter industry more than 10 years experience for you with satisfactory service. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
To that end, Beijing Sincerity Automatic Equipment Co., Ltd has successfully built a solid foundation and infrastructure for mass flow meter manufacturing.
Make your v shape coriolis mass flow meter coriolis mass flow meter emerson. Invest in professional mass flow meter services. For more info, check out Sincerity Flow Meter.
The more people who do a certain thing, the more likely others are to do it as well. When Sincerity can demonstrate their popularity or satisfaction across a wide customer base, other consumers are more likely to buy in as well.
mass flow meter is produced by Beijing Sincerity Automatic Equipment Co., Ltd’s professional skills in high technology.
Utilizing high technology to manufacture products can afford a fully experience to customers by using mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com