V cone flowmeter scale installation technical requirements and matters needing attention
by:Sincerity Group
2020-11-07
Abstract: the technology of V cone flowmeter scale installation requirements and matters needing attention of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation.
Weinan and shunda meter manufacturers V cone flowmeter is a kind of high precision, high stability, wide range than wide, measurable medium of the new type of flowmeter, flow is based on the principle of continuity and Bernoulli equation to calculate the working condition of fluid flow, the pressure and flow rate.
More flow meter manufacturers choose model price quote you are welcome to inquire, here is a V cone flowmeter scale installation details the technical requirements and matters needing attention of the article.
Flow meter manufacturers V cone flowmeter is a kind of high precision, high stability, wide range than wide, measurable medium of the new type of flowmeter, flow is based on the principle of continuity and Bernoulli equation to calculate the working condition of fluid flow, as pressure, velocity, or big or hours, the differential pressure value is also changed.
So V cone flowmeter differential pressure flowmeter is also known as one of them, for V cone flowmeter measurement accuracy is relatively high.
Therefore become the preferred flowmeter in the middle of the industrial field.
The following detailed introduce V cone flowmeter to users in the installation of the technical requirements and matters needing attention have?
1, V cone flow meter installed technical requirements: (
1)
V cone flowmeter is installed on the line, can be a level, it can also be tilted, also can be vertical, but should be easy installation and maintenance is advisable.
(
2)
V cone flowmeter must be installed in line with its corresponding nominal diameter.
(
3)
V cone flowmeter of upstream and downstream straight pipe should be circular, the lining is smooth, its diameter is the same as the nominal diameter flowmeter.
(
4)
When installing, the flow of V cone flowmeter must be consistent with the flow of fluid.
If the installation location of the ambient temperature more than 70 & deg;
Fission installation form C, recommended.
(
5)
V cone flowmeter in the upstream and downstream side should be configured with a certain length of straight pipe, the length should satisfy the upstream 0 ~ 3 d, downstream 0 ~ 1 d, long straight pipe for flow measurement.
(
6)
V cone flow timing in, should as far as possible to ensure that the upstream or downstream flow meter and straight pipe concentric.
(
7)
If the site does need to install the thermometer, regulating valve, and other measurement and control device, good advice zui installed in the downstream end of the 2 ~ 5 d V cone flowmeter.
2, the installation V cone flow timing, matters need to pay special attention to: (
1)
When choosing a type V cone flowmeter, shall, according to the user's requirements, process parameters and the field environment, combining the technical parameters of V cone flowmeter selection appropriate product model.
(
2)
In choosing a V cone flow time, pipe diameter must be filled in according to the actual diameter circle.
(
3)
Select V cone flowmeter in writing model, part function is only applicable to intelligent integration of V type flowmeter.
(
4)
In choosing a V cone flow time, attention should be paid to the choice of temperature and pressure compensation function: a.
In choosing a V cone flow timing, liquid without compensation.
b。
In choosing a V cone flow timing, measuring gas should be with temperature and pressure compensation.
c。
In choosing a V cone flow timing, measuring the saturated steam should temperature compensation.
d。
In choosing a V cone flow timing, superheated steam temperature and pressure should be brought in compensation.
(
5)
In choosing a V cone flow time, the user to specify transmitter, should consult technical parameters in the transmitter, determine the integration.
Flow meter manufacturer with many years engaged in the flow meter automation professional technical talent and rich experience in after-sales service, to provide users with design, production, installation, debugging, the entire journey service, people-oriented, wholeheartedly for the customer service is the principle of flow meter.
Manufacturer for many years operating objective is: quality *, the good faith management, door-to-door service is a shortcut to our communication with the customers, quality excellence, customer satisfaction.
Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd who is highly knowledgeable about manufacturing as well as selling and confident in our ability to create finest products as mass flow meter digital fork density meter.
Many websites provide additional information on the topic of mass flow meter. One such site worth visiting is Sincerity Flow Meter.
Using high-quality materials to produce mass flow meter is one of the most important part during manufacturing.
Beijing Sincerity Automatic Equipment Co., Ltd also has an extensive line of products as mass flow meter.
This can benefit Sincerity by helping it target those investors and consumers who are specifically interested in its type of product or service.
Beijing Sincerity Automatic Equipment Co., Ltd who is highly knowledgeable about manufacturing as well as selling and confident in our ability to create finest products as mass flow meter digital fork density meter.
Many websites provide additional information on the topic of mass flow meter. One such site worth visiting is Sincerity Flow Meter.
Using high-quality materials to produce mass flow meter is one of the most important part during manufacturing.
Beijing Sincerity Automatic Equipment Co., Ltd also has an extensive line of products as mass flow meter.
This can benefit Sincerity by helping it target those investors and consumers who are specifically interested in its type of product or service.
Custom message