Abstract: The information on the use and maintenance of vortex flowmeters is provided by excellent flowmeter and flowmeter manufacturers. 1 The working principle of vortex flowmeter Vortex flowmeter belongs to velocity flowmeter, which is composed of transmitter and signal converter composed of vortex generator and frequency detector. The measurement principle is that in the flowing fluid, if it is placed perpendicular to the flow direction. More flowmeter manufacturers select models and price quotations. You are welcome to inquire. The following are the details of the use and maintenance of vortex flowmeters. 1 The working principle of vortex flowmeter Vortex flowmeter belongs to velocity type flowmeter, which is composed of transmitter and signal converter composed of vortex generator and frequency detector. The measurement principle is that in the flowing fluid, if a vortex generator is placed in the vertical flow direction, within a certain Reynolds number range, regular vortices will be generated alternately on both sides behind the vortex generator (see Figure 1). The rows of vortices are arranged asymmetrically downstream of the vortex generator. Fig. 1 Vortex generator and vortex Let the frequency of vortex generation be f, the average flow velocity of the measured medium is v, and the width of the vortex generator head to be d. where Sr is a function of Reynolds number, at ReD=2×104~7×In the range of 106, Sr can be regarded as a constant, and the vortex frequency is proportional to the volume flow. The vortex flowmeter can measure the flow of liquid, gas and steam in a single state. In the state of miscible fluid, the flowmeter cannot make accurate measurements. Vortex flowmeters are available in one-piece and split-type. 2 Installation of vortex flowmeter Vortex flowmeter is divided into flange type, clamp type and insertion type according to the sensor. When selecting the type, the flange type is given priority, followed by the clamp type, and the plug-in type is not considered. The reason is that the accuracy of the clamp-type and insertion-type flow meters is greatly affected by the installation, and the non-standard installation will produce a large measurement error. The installation of the vortex flowmeter must ensure that the arrow on the sensor nameplate is pointing in the same direction as the fluid flow and must meet the minimum front and rear straight pipe requirements in the figure below. At the same time, the following requirements must be observed. 2.1 Installation of measuring gas or steam flowmeter When measuring gas or steam, the vortex flowmeter should be installed on a horizontal pipeline, and attention should be paid to prevent liquid from stagnant when piping. The pipe section of the street flow meter is raised. The vortex flowmeter is installed on the vertical pipeline, and the flow direction is not limited. If the measured gas contains a small amount of liquid, the gas flow should be from bottom to top, as shown in Figure 2. Figure 2 Schematic diagram of installation of vortex flowmeter for measuring gas or steam 2.2 Installation of measuring liquid flowmeter To ensure accurate measurement, the pipeline of vortex flowmeter must be filled with liquid. When the vortex flowmeter is installed on a horizontal pipeline, the pipeline in the downstream section should be higher than the vortex flowmeter to keep the pipe full; when the fluid flows downward, the pipeline in the downstream section should be higher than the vortex flowmeter to avoid Keep the tube full. When the flowmeter is installed on a vertical pipe, the fluid should flow upwards, and when the fluid flows downwards, the downstream section of the pipe should be higher than the vortex flowmeter to keep the pipe full, as shown in Figure 3. Figure 3 Schematic diagram of installation of vortex flowmeter for measuring liquid 2.3 Positional relationship between flowmeter and control valve impact, see Figure 4. When the vortex flowmeter is installed in a horizontal pipeline, when the temperature of the measured medium is greater than 200 °C, the transmitter must be installed with the head down. Figure 4 The position of the vortex flowmeter and control valve The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Use and Maintenance of Vortex Flow Meters'
mass flow meter are all following the most compatible manufacturing regulations.
Beijing Sincerity Automatic Equipment Co., Ltd is one of China's biggest providers in the following categories of products: mass flow meter, electromagnetic flow meter slurry, rosemount vortex flow meter,etc. We also welcome ODM and OEM orders, and offer the highest standards of service, the cheapest deals, and the best buying experience. Get to know us at Sincerity Flow Meter.
Apart from this, exhibit myriad u shape coriolis mass flow meter benefits, like the prevention of fork density meter manufacturer by enhancing digital fork density meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com