Abstract: ultrasonic flowmeter scale performance and use of the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Abstract: the article discusses the relevant problems of using ultrasonic flowmeter measurement of liquid flow, mainly illuminates the ultrasonic flowmeter measurement principle, installation, use and calibration, and combined with glaxo wellcome ( Suzhou) Details introduction SERIEST pharmaceutical co. , LTD. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the performance of the ultrasonic flowmeter scale and the use of the article details. This paper discusses the use of ultrasonic flowmeter measurement issues related to the liquid flow, mainly illuminates the ultrasonic flowmeter measurement principle, installation, use and calibration, and combined with glaxo wellcome ( Suzhou) Pharmaceutical details the use of SERIESTFX series ultrasonic flowmeter are introduced. 1. Problem of my company has more flow measuring instruments, in the common system process of fluid flow, the velocity measurement of important parameters such as control. A set can accurately reflect actual usage of fluid measurement device is very necessary. Therefore, in order to improve the level of measurement, guarantee the accuracy of the measuring instruments can show that, after careful analysis of the system research, in combination with the practical situation of our company, we by adopting rotor flowmeter measurement, gradually into the use of ultrasonic flowmeter measurement. System is running for 3 years, greatly improve the measurement accuracy, and install, easy to use, in order to gain the obvious economic benefits. 2. Principle is introduced at present generally use two types of ultrasonic flowmeter, a kind of multiple doppler ultrasonic flowmeter, another kind is the jet lag type ultrasonic flowmeter. Type doppler velocity is using the method of phase difference measurement, namely a known frequency of sound waves in the fluid movement, caused by the liquid itself has a velocity, the ultrasonic in the two receivers ( Or transmitter) Between the relative frequency or phase change, can be obtained by measuring the relative changes in liquid velocity; Jet lag is using the method of time difference measuring velocity, namely a velocity of sound waves due to fluid flow and makes it in two receivers ( Or transmitter) Between travel time change, can be obtained by measuring the relative changes in fluid flow velocity. Currently USES the time difference ultrasonic flowmeter. 3. Installation method introduces usually adopt three kinds of installation method: W, V, Z. According to the different pipe diameter and flow characteristics to select installation, W is suitable for small diameter (usually 25 ~ 75毫米) , V is suitable for the pipe diameter ( 25 ~ 250毫米) , Z type is suitable for big diameter ( More than 250 mm) , in short, in order to improve measurement accuracy and sensitivity, choose the appropriate installation, the measurement signal ( The difference) Match the secondary instrument. I used the Z type installed at present. In order to ensure the measurement accuracy, should choose to meet certain conditions of location positioning: usually choose above 10 d, 5 d downstream of straight pipe upstream; The upstream within 30 d cannot load disturbance equipment such as pump, valve. For my company Z installation, introduction to ultrasonic flowmeter sensor installation method, the specific use & quot; Coordinate method of installation & quot; , namely the pipe outside surface processing clean first, coated with special coupling agent, the first one of the probe position, use tape around pipeline, measure the perimeter folded tag, 1/2 of the circumference determine another probe orbit position, the same orbit should be parallel to the axis of pipe, according to the installation of the instrument shows distance, determine the relative distance of two probe in orbit, to ensure that the ultrasonic have enough signal intensity, often make panel shows the signal strength is greater than 2%, for reading showed stable, end of the installation and debugging, the instrument can work normally. 4. The use of flowmeter ( 1) Zero flow check line when liquid static and around without strong magnetic field interference, under the condition of strong vibration, header shows zero, automatically set zero point at this time, eliminate the zero drift, the runtime must to remove small signal, usually less than 5% of the full process flow, flow automatically removed. At the same time zero point can be adjusted through the menu. ( 2) Instrument panel keyboard operation, before start the meter running effectively for the parameters of the first set, for example, using the system, installation, pipe diameter, pipe wall thickness, pipe material, pipe roughness, fluid type and the distance between two probes, velocity of flow unit, zui small speed, large zui, etc. Only if all input parameters correctly, instrument can display correctly the actual flow rate value ( 3) Flowmeter calibration in order to ensure the accuracy of the flow, we conduct regular check, usually we adopt direct comparison of the portable flowmeter, higher precision, using the test data to compute error = ( Measured values - Standard) / standard, using the calculation of relative error, the correction coefficient, the measurement error to meet & plusmn; An error of 2%, can satisfy the measurement requirements. This simple and convenient operation, can effectively improve the accuracy of measurement. 5. Conclusion flow is the enterprise energy consumption index, is one of the important parameters of the agent during the process of enterprise production, flow meter get more and more application, with the rapid development of science and technology, the high precision, high reliability, high intelligent instruments made her very popular. I companies choose SERIESTFX ultrasonic flowmeter embody convenient installation, reliable measurement, the characteristics of easy to operate. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd works very hard to understand your objectives, then create a program that can help you meet them.
Visit Beijing Sincerity Automatic Equipment Co., Ltd in China for professional mass flow meter tips and qulity ensured . The company is a licensed, bonded, and insured provider with decades of experience. Make your enquiry, today.
digital fork density meter mass flow meter is characterized by various advantages, such as rosemount vortex flow meter, rosemount coriolis mass flow meter and v shape coriolis mass flow meter, which is not the case with other mass flow meter.
For more mass flow meter insertion ultrasonic flow meter reviews, tips and advice on choosing a washer and dryer for you and your family, please visit Sincerity Flow Meter,where you can also choose the you are looking for.
Beijing Sincerity Automatic Equipment Co., Ltd's core technology of mass flow meter enables us to understand and utilize in a right way.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com