Abstract: the scale vortex flowmeter selection advice information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Vortex street flowmeter selection Suggestions: 1. Used in the measurement occasions, especially the trade settlement amount 10 vme recommends to the pulse signal output flow sensor instead of using 10 vte flow transmitter. Reason: the flow sensor output pulse signal separation and vortex frequency directly. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a scale vortex flowmeter selection advice article details. Vortex street flowmeter selection Suggestions: 1. Used in the measurement occasions, especially the trade settlement amount 10 vme recommends to the pulse signal output flow sensor instead of using 10 vte flow transmitter. Reason: the flow sensor output pulse signal separation and vortex frequency corresponding to the directly, has high zui cumulative accuracy. The pulse signal transmission effect is good, at the same time, low cost flow transmitter. Flow transmitter is analog signal output, full range accuracy, accumulative total accuracy is poor, not suitable for the total measurement purposes. 2. Under normal circumstances, the flange is recommended for the card type flowmeter. It is more compact than flange connection structure of flowmeter, the price also is low. 3. At the scene of the explosion danger, should use explosion-proof type flowmeter. Because of the flameproof instrument for the dangerous sites are not allowed to be used to 0 class, flameproof instrument at the same time does not allow at the scene with some open shell circuit adjustments, so, it is strongly recommended that users try to use this type explosion-proof vortex flowmeter. Only under special circumstances to consider to choose flameproof flowmeter. 4. Carefully chosen DIN/ANSI standard flowmeter. DIN/ANSI meter do not match the actual diameter and GB international pipeline diameter, when the pipeline to be tested is GB international pipeline, if manufactured by DIN/ANSI standard flow meter, will encounter the problems of the installation and use. Only under the condition of pipe is DIN/ANSI piping, only use DIN/ANSI standard flowmeter. 5. Standard material 1 cr18ni9ti can be applied to most of the conventional medium, including some of the corrosive medium and saturated steam, superheated steam. The special high corrosive medium without using special materials, which is expensive, processing period is long. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
An increasing dependence on the use of mass flow meter digital fork density meter has made numerous changes in the rosemount coriolis mass flow meter industry over the past decades.
Looking for a company to handle your mass flow meter fork density meter manufacturer? Visit Sincerity Flow Meter today for more information.
Beijing Sincerity Automatic Equipment Co., Ltd have significantly changed the way customers approach manufacturing. mass flow meter can still compete if we are willing to change the ways in producing.
Your co-workers, investors and clients have busy schedules, and it can be hard to get everyone in the same place at the same time for mass flow meter. So, it is important to create a connection between company and clients.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com