loading

Sincerity Group | Coriolis flow meter manufacturers| 


LG orifice flow meter installation requirements and precautions

Abstract: The installation requirements and precautions of LG orifice flow meter are provided by excellent flow meter and flow meter manufacturers. 1. Pipeline conditions: (1) The straight pipe section before and after the throttle must be straight, and there must be no visible bending. (2) The straight pipe section used to install the throttling should be smooth. If it is not smooth, the flow coefficient should be multiplied by the roughness to correct the sparseness. (3) To ensure the flow of fluid. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the installation requirements and precautions of LG orifice flowmeters. 1. Pipeline conditions: (1) The straight pipe section before and after the throttle must be straight, and there must be no visible bending. (2) The straight pipe section used to install the throttling should be smooth. If it is not smooth, the flow coefficient should be multiplied by the roughness to correct the sparseness. (3) In order to ensure that the flow of the fluid forms a fully developed turbulent velocity distribution 1D before the throttling member, and make this distribution a uniform axisymmetric shape, so 1) the straight pipe section must be round, and the throttling must be round. In the 2D range before the piece, the roundness requirements are very strict, and there are certain roundness indicators. Specific measurement method: (A) On the OD, D/2, D, 2D 4 vertical pipe sections before the throttling piece, measure at least 4 single measurement values ​​of the inner diameter of the pipe with a large to equal angular distance, and take the average value D. The difference between the single measured value of any inner diameter and the average value shall not exceed±0.3% (B) After the throttling piece, 8 single measurement values ​​of inner diameter are measured by the above method at the OD and 2D positions, and the maximum deviation of any single measurement value compared with D shall not exceed±2% 2) A long enough straight pipe section is required before and after the throttling piece. This long enough straight pipe section is related to the form of the local resistance piece before the throttling piece and the diameter ratioβFor details, see Table 1 (β=d/D, d is the opening diameter of the orifice plate, and D is the inner diameter of the pipe). (4) The length of the straight pipe section between the resistance member and the second resistance member on the upstream side of the throttling member can be in the form of the second resistance member andβ=0.7 (regardless of the actualβWhat is the value) Take 1/2 of the value listed in Table 1 (5) The upstream side of the throttle is the open space or diameter≥In the case of a 2D large container, the straight pipe length between the open space or the large container and the throttling piece shall not be less than 30D (15D). If there are other local resistance parts between the throttling piece and the open space or the large container, the In addition to the minimum straight pipe length 1 specified in Table 1, the total length of the straight pipe from the open space to the throttling element shall not be less than 30D (15D). The minimum straight pipe section length on the upstream and downstream sides of the throttling piece Table 1 The form of the local female part on the upstream side of the throttling piece and the minimum straight pipe section length L Note: 1. The above table is only for standard throttling devices, and can be used for special throttling devices For reference 2. The number of columns is a multiple of the inner diameter D of the tube. 3. The numbers outside the parentheses in the above table are“Additional relative limit error is zero”, the numbers in parentheses are“The additional relative limit error is±0.5%”value of . That is, when there is a value in parentheses in the length of the straight pipe, the limit relative error τQ/Q of flow measurement. It should be arithmetically added by 0.5%, that is (τQ/Q+0.5)%“Additional limit relative error of 0.5%”deal with. (1) The straight-through part is installed in the pipeline, its front end must be perpendicular to the axis of the pipeline, and the maximum allowable non-perpendicularity shall not exceed±1°. (2) After the throttling piece is installed in the pipeline, its opening must be concentric with the pipeline, and the maximum allowable misalignment ε shall not exceed the calculation result of the following formula: ε≤0.015D(1/β-1). (3) All gaskets should not be made of too thick material, preferably no more than 0.5mm, and the gaskets should not protrude into the pipe wall, otherwise it may cause a large measurement error. (4) Any valve used to adjust the flow should be installed beyond the minimum length of the pipe section after the throttling part. (5) The installation of the throttling device on the process pipeline must be carried out after the pipeline is cleaned and purged. (6) The pressure taking method of the throttling device installed in the horizontal or inclined pipeline. 1) When the fluid to be tested is liquid, in order to prevent air bubbles from entering the process pipeline and entering the jaws, the pressure-receiving buckle should be located at the lower part of the center line of the process pipeline.≤45°The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'LG orifice flow meter installation requirements and precautions'

Beijing Sincerity Automatic Equipment Co., Ltd is different from other companies as we provide timely and unique services to our respected clients.

Beijing Sincerity Automatic Equipment Co., Ltd is an expert manufacturer that offers top-notch endress hauser coriolis mass flow meter mass flow meter products in digital fork density meter. The company has a a lot of experience to offer quality ensured that cater to various customer demands. Simply visit Beijing Sincerity Automatic Equipment Co., Ltd website to learn more.

In the boundless Chinese market, there are a number of enterprises that provides insertion ultrasonic flow meter mass flow meter of their own brand over the years, but few have won more support from customers on the international stage than Sincerity.

It is essential to know the basic functioning of to help us understand the components and the part they play.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect