loading

Sincerity Group | Coriolis flow meter manufacturers| 


Installation Precautions for Turbine Flow Meters

Abstract: Information on installation precautions for turbine flowmeters is provided by excellent flowmeter and flowmeter manufacturers. Turbine flowmeters are widely used to measure liquids in closed pipelines with stainless steel 1Cr18Ni9Ti, 2Cr13, corundum AI2O3, and hard alloys that do not corrode, and have no impurities such as fibers and particles. The kinematic viscosity at working temperature is less than 510-6m2/s. For kinematic viscosity greater than 51. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the article on the installation precautions of turbine flowmeters. Turbine flowmeter is widely used in the measurement of closed pipeline with stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum AI2O3, hard alloy has no corrosion effect, and no impurities such as fibers, particles, kinematic viscosity at working temperature is less than 5×10-6m2/s liquid, for kinematic viscosity greater than 5×The liquid of 10-6m2/s can be used after real-liquid calibration of the flowmeter, and it can also be used for quantitative control, over-amount alarm, etc. It is an ideal instrument for flow measurement and energy saving. Precautions for installation: 1. The horizontally installed sensor of the turbine flowmeter requires that the pipeline should not have a visually observable inclination (5°within) the vertical deviation of the sensor pipeline installed vertically should be less than 5°, the fluid direction should be down and up. 2 Where the flow cannot be stopped, bypass and stop valves should be installed. If the fluid contains impurities, a filter should be installed on the upstream side; if it contains gas, an air eliminator should be installed on the upstream side. The sewage outlet and air outlet of the filter and air eliminator should lead to a safe place. 3 The flow regulating valve should be installed downstream of the sensor, and the upstream stop valve should be fully open during measurement, and neither vibration nor leakage should be generated. For processes that may produce reverse flow, a check valve should be added to prevent reverse flow of the fluid. 4 The sensor should be concentric with the pipeline, and the sealing gasket should not protrude into the pipeline. The sensor should not be at the high point of the horizontal pipeline, so that the gas accumulated in the pipeline (such as air mixed in when the flow is stopped) stays at the sensor, which is not easy to be discharged and affects the measurement. 5. The pipelines before and after the sensor should be supported firmly without vibration. For condensable fluids, thermal insulation measures should be taken for the sensor and its front and rear pipelines. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Installation Precautions for Turbine Flow Meter'

If you are a digital fork density meter fan, you definitely want to enjoy the best possible. The that you choose plays a major role with the kind of experience you have when using it.

Beijing Sincerity Automatic Equipment Co., Ltd’s goal is to provide the customer with an enjoyable, honest service by satisfying individual customers practical transportation needs with a quality product.

What Beijing Sincerity Automatic Equipment Co., Ltd discovered was that innovation occurs when business models match up with one or more of the mass flow meter where technological advances overlap with market needs, thus resulting in growth and transformation.

Beijing Sincerity Automatic Equipment Co., Ltd are used to coming up with solutions while think about problems, also expressing the whole idea individually.

Unlike the insertion ultrasonic flow meter, the is more flexibly used in accasions where fork density meter manufacturer .

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect