Abstract: The more accurate information on how to install the steam flow meter is provided by the excellent flow meter and flow meter production and quotation manufacturers. It mainly involves the following aspects: 1. The problem of flowmeter selection. Some vortex sensors choose a larger size due to changes in process conditions in the caliber selection or after the design and selection, and the actual selection should choose the smallest caliber as possible. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is a more accurate article on how to install steam flowmeters. It mainly involves the following aspects: 1. The problem of flowmeter selection. Some vortex sensors choose a larger size due to changes in process conditions in the caliber selection or after the design and selection. The actual selection should choose the smallest caliber to improve the measurement accuracy. The reasons for this are mainly the same as Questions ①, ③, ⑥ are related. For example, a vortex pipeline is designed to be used by several equipments. Due to the fact that some of the equipment in the process are sometimes not used, the current actual flow rate is reduced. The actual use causes the original design selection diameter to be too large, which is equivalent to increasing the measurable flow rate. The lower limit, the indication cannot be guaranteed when the flow rate of the process pipeline is small, and it can be used when the flow rate is large, because it is sometimes too difficult to remodel. Changes in process conditions are only temporary. Can be combined with parameter re-tuning to improve indication accuracy. 2. The installation of vortex flowmeter. The main reason is that the length of the straight pipe section in front of the sensor is not enough, which affects the measurement accuracy. The reason for this is mainly related to problem ①. For example, the straight pipe section in front of the flow sensor is obviously insufficient. Since FIC203 is not used for measurement, it is only used for control, so the current accuracy can be equivalent to degraded use. 3. The reason for the parameter setting direction. Due to wrong parameters, the instrument indication is wrong. The parameter error makes the calculation of the full-scale frequency of the secondary instrument wrong, and the reason for this is mainly related to the problems ① and ③. The similar full-scale frequency makes the indication inaccurate for a long time, and the actual full-scale frequency greatly affects the calculated full-scale frequency, which makes the indication fluctuate in a large range and cannot be read, and the inconsistency of the parameters on the data affects the final determination of the parameters, and finally passed Recalibration combined with mutual comparison to determine the parameters solves this problem. 4. Secondary instrument failure. There are many faults in this part, including: there is a disconnection on the circuit board of the instrument, the display of the individual digit of the range setting is broken, and the display of the individual digit of the K coefficient setting is broken, making it impossible to determine the range setting and K coefficient setting. Part of the reason is mainly related to problems ① and ②. By fixing the corresponding failure, the problem is solved. 5. Four-way line connection problem. On the surface of some circuits, the circuit connection seems to be very good. After careful inspection, some connectors have actually been loose, causing the circuit to be interrupted. Although some connectors are tightly connected, the fastening screws are fastened to the wire sheath due to the problem of the auxiliary line, which also makes the circuit breaker. Interruption, this part of the reason is mainly related to problem ②. The corresponding line problems are solved, and the existing problems are also solved accordingly. 6. The connection between the secondary instrument of the vortex flowmeter and the subsequent instrument. Due to the problem of the follow-up instrument or the maintenance of the follow-up instrument, the mA output circuit of the secondary instrument is interrupted. For this type of secondary instrument, this part of the reason is mainly related to problem ②. Especially for the subsequent recorder, when the recorder is damaged for a long time and cannot be repaired, be sure to short-circuit the output of the secondary meter. 7. The circuit has no indication due to the fault of the flat shaft cable of the secondary instrument. Due to long-term operation and the influence of dust, the flat shaft cable is faulty, and the problem can be solved by cleaning or replacing the flat shaft wire. 8. For the problem ⑦, it is mainly due to the looseness of the fixing screw of the coil on the display of the secondary instrument, which causes the head to sink, the friction between the pointer and the case is large, and the action does not work well. By adjusting the head and fixing it again, the problem is solved accordingly. 9. Environmental problems in the use of flowmeters. Especially for the sensor part installed in the ground well, the circuit board is damp due to the high ambient humidity. This part of the reason is mainly related to problems ② and ②. Through the corresponding technical improvement measures, some sensors with high environmental humidity have been re-separated from the probe part and the conversion part, and a separate sensor has been used, so the working environment has been improved. Recently, this part of the instrument runs well. 10. Due to poor on-site adjustment, or due to changes in the actual situation after adjustment. Due to the on-site vibration and noise balance adjustment and sensitivity adjustment is not good. Or due to the change of the on-site situation after the adjustment and running for a period of time, the indication problem is caused. This part of the reason is mainly related to the problems ④ and ⑤. Use an oscilloscope, plus the process operation, to readjust. 11. The reason why problem ⑧ is raised separately is that this problem has affected the analysis and solution of the problem for a long time. Since Dongfang Chemical Plant does not have the K coefficient calibration conditions,The K coefficient can only be based on the information provided by the manufacturer. Due to some changes in the manufacturer itself, the K coefficient in the provided information is inconsistent, which affects the solution of the problem. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'How to install a steam flow meter more accurately'
Beijing Sincerity Automatic Equipment Co., Ltd promises that we will manufature our products in accordance with the strictest quality standards.
Super quality are in offer at Sincerity Flow Meter, welcome to visit us.
To find a qualified at reasonable price, contact Beijing Sincerity Automatic Equipment Co., Ltd at Sincerity Flow Meter, a professional provider and tell them what you envision for your mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com