loading

Sincerity Group | Coriolis flow meter manufacturers| 


Flow meter installation requirements and environmental factors to be considered

Abstract: The information on the installation requirements of flow meters and the environmental factors that should be considered are provided by the excellent manufacturers of flow meters and flow meters. Flowmeter installation 1. Problems to be paid attention to during installation Installation problems have different requirements for flowmeters with different principles. For some flowmeters, such as differential pressure flowmeters and velocity flowmeters, according to regulations, the upstream and downstream of the flowmeter must be equipped with a certain length. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following are the details of the installation requirements of flowmeters and environmental factors that should be considered. Installation of flowmeters 1. Problems to be paid attention to during installation Installation problems have different requirements for flowmeters of different principles. For some flowmeters, such as differential pressure flowmeters and velocity flowmeters, according to the regulations, a certain length or a long straight pipe section should be equipped upstream and downstream of the flowmeter to ensure that the fluid flow before the inlet end of the flowmeter is fully developed. . While other flowmeters, such as positive displacement flowmeters, float flowmeters, etc., have no or lower requirements on the length of straight pipe sections. Some flowmeters have certain errors due to the influence of installation. For example, Coriolis mass flowmeters will bring great errors to use due to the influence of installation stress. Problems in the use of retrospective flowmeters may not necessarily be due to the problems of the flowmeter itself, and many situations are caused by poor installation. The common problems are as follows: ① Reverse the inlet surface of the orifice plate of the differential pressure flowmeter; ② The flow sensor is installed in a place with a poor flow velocity distribution profile; ④ The flow meter is installed in a harmful environment or a place that is not easily accessible; ⑤ The flow direction of the flow meter is installed in the wrong direction; ⑥ The flow meter or electrical signal transmission line is placed in a strong electromagnetic field; On the pipeline with vibration; ⑧ lack of necessary protective fittings. 2. Installation conditions The flowmeter should pay attention to the adaptability and requirements of the installation conditions during use, mainly from the following aspects, such as the installation direction of the flowmeter, the flow direction of the fluid, the configuration of upstream and downstream pipelines, valve position, protection Accessories, pulsating flow effects, vibration, electrical disturbances and flowmeter maintenance, etc. ① On-site pipeline wiring When wiring on-site pipelines, attention should be paid to the installation direction of the flowmeter. Since the installation direction of the flowmeter is generally divided into vertical installation method and horizontal installation method, the flow measurement performance is different for these two installation methods. For example, the vertical downward flow of the fluid will cause additional force to the flowmeter sensor, which will affect the performance of the flowmeter, and reduce the linearity and repeatability of the flowmeter. The installation direction of the flowmeter also depends on the physical properties of the fluid. For example, the horizontal pipeline may precipitate solid particles. Therefore, it is best to install the flowmeter with this state in the vertical pipeline. ② The flow direction of the fluid This problem is similar to the installation direction of the flowmeter. Since some flowmeters can only work in one direction, reverse flow will damage the flowmeter. The use of similar flowmeters also considers the possibility of reverse flow in the event of inactivity, which necessitates measures such as installing check valves to protect the flowmeter. Even a flowmeter that can be used in both directions may have some differences in measurement performance between forward and reverse, and should be used as specified by the manufacturer. ③ The upstream and downstream straight pipe sections of the flowmeter will be affected by the flow state of the pipeline inlet, and the pipe fittings will also introduce flow disturbance. The flow disturbance generally includes vortex and flow velocity distribution profile distortion. Caused by more than one space (stereo) elbow. Distortion of the velocity profile is usually caused by local obstructions in pipe fittings (eg valves) or elbows. These effects need to be ameliorated with upstream straight runs of appropriate lengths or the installation of flow conditioners. In addition to considering the influence of the flowmeter connection fittings, you may also consider the influence of the combination of upstream pipe fittings, because they may generate different disturbance sources, so be sure to keep the distance between the disturbance sources as much as possible to reduce their influence. For example, a partially open valve follows immediately after a single bend. A straight pipe section is also required downstream of the flowmeter to reduce downstream flow effects. For volumetric flowmeters and Coriolis mass flowmeters, they are not affected by asymmetric flow profiles; turbine flowmeters should be used to minimize vortex; electromagnetic flowmeters and differential pressure flowmeters should limit the vortex to a small within the range.

The use and installation of mass flow meter is compared with most other systems for managing the rosemount vortex flow meter effectively and no doubt mass flow meter have won the race so many times.

Beijing Sincerity Automatic Equipment Co., Ltd is a professional manufacturer of offering some of the best in class mass flow meter solutions to global market. Click Sincerity Flow Meter to learn more.

With a complete manufacturing plant, Beijing Sincerity Automatic Equipment Co., Ltd is able to meet the most stringent specifications, no matter the type of product. A dedicated team of experts handle these value-added services, ensuring that customer needs are met on time, consistently monitoring quality and performance of mass flow meter to the highest international standards. Visit Sincerity Flow Meter to learn more.

With this competency, Beijing Sincerity Automatic Equipment Co., Ltd provide high technology and assist customers to create added value and contribute to the development of producing mass flow meter.

Beijing Sincerity Automatic Equipment Co., Ltd offers the best for indoor as well as outdoor use. To find your ideal at attractive offers, visit us at Sincerity Flow Meter.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect