Abstract: The information on the five steps of using the precession vortex flowmeter is provided by the excellent flowmeter and flowmeter manufacturers. At present, the gas flowmeters often used by enterprises in working conditions mainly include precession vortex flowmeter, gas turbine flowmeter, vortex flowmeter, orifice flowmeter, Verabar flowmeter, V-cone flowmeter, metal tube rotameter, Del Taba flowmeter, etc. which spin. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the five-step article using the precession vortex flowmeter. At present, the gas flowmeters often used by enterprises in working conditions mainly include precession vortex flowmeter, gas turbine flowmeter, vortex flowmeter, orifice flowmeter, Verabar flowmeter, V-cone flowmeter, metal tube rotameter, Del Taba flowmeter, etc. Among them, the precession vortex flow sensor is a sensor widely used in various gas flow measurement in petroleum, chemical, electric power, metallurgy, urban gas supply and other industries. The correct use of the precession vortex flow sensor must follow the following five requirements, so as to ensure the measurement accuracy. 1. Correct selection of precession vortex flowmeter is widely used in natural gas, gas and other industries, with stable performance, accurate measurement, and convenient installation. When it has been determined to choose a precession vortex flowmeter, the next step is to determine the flow sensor specifications and The selection of its kits is critical. In a word, you can use it well when you choose it. To this end, two basic principles should be grasped in the selection process; namely: one must ensure the accuracy of use, and the other must ensure production safety. To do this, three selection parameters must be implemented, namely, the maximum, minimum and commonly used instantaneous flow rates in the near and long term, the design pressure of the measured medium, and the working pressure. 2. Calibration before use On the one hand, considering that there are still some difficulties in on-site verification of this type of flow sensor. In addition, if the purchase intention is to use this kind of flow sensor in more important measurement occasions, such as large-flow trade measurement or measurement points with prominent measurement disputes, and the application site does not have the conditions for online calibration of flow, In this case, it is too early to easily determine that all the performances of the flow sensor are qualified based on a factory certificate provided by the manufacturer at the time of purchase. Therefore, in order to ensure the reliability and accuracy of the measurement results of the flow sensor in the future work process, it is necessary to send the flow sensor to the department with the verification ability and qualification for a system verification within the full flow range before the formal installation. . 3. Do a good job in process installation Although this kind of flow sensor does not have too many special requirements for process installation and use environment, any type of flow measurement instrument has such a commonality, that is to avoid vibration and high temperature environment as far as possible. Interfering elements, keeping the inner wall of the straight pipe section before and after the flow sensor smooth and straight, ensuring that the measured medium is a clean single-phase fluid, etc. 4. Strengthen later management Although the precession vortex flowmeter has the characteristics of various automatic disposal functions and low power consumption, it still needs to strengthen the management after it is put into operation. For example, in order to ensure the accuracy and reliability of the long-term operation of the flow sensor, it is necessary to regularly calibrate the system, copy the meter data, replace the medium parameters, check the battery status from time to time, check the flow sensor coefficient and lead seal, etc. 5. Pay attention to internal maintenance. If the measuring cavity of the flow sensor and its components need to be regularly inspected or cleaned due to air pollution or other reasons, then one point must be paid special attention: for the precession vortex flow sensor of the same specification, its vortex The core components such as the generator and the conducting body cannot be interchanged. Otherwise, the metering coefficient must be re-calibrated and the temperature and pressure sensors attached to it must be systematically calibrated. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Five Steps to Using a Precession Vortex Meter'
Competitiveness policy of Beijing Sincerity Automatic Equipment Co., Ltd is about existing clusters as a platform for upgrading microeconomic fundamentals, where structural policies aim to change the industrial composition of an economy more directly.
Providing highly qualified mass flow meter products and services, Beijing Sincerity Automatic Equipment Co., Ltd is committed to helping clients make lasting improvements to their performance and realize their most important goals. Over the past decades, we’ve built a firm uniquely equipped to this task. Go to Sincerity Flow Meter for more info.
Do you want to find a provider to get your mass flow meter problem settled? If so, we suggest that you give a shot to Beijing Sincerity Automatic Equipment Co., Ltd. Visit Sincerity Flow Meter to learn more and contact us.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com