loading

Sincerity Group | Coriolis flow meter manufacturers| 


All kinds of flow meter scale selection principle and method

Abstract: various meter scale selection principle and method of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. One, the principle of flowmeter selection choose the principle of flow meter was first to deep understanding of the fundamentals of the structure of the flow meter and flow characteristics of knowledge, even at the same time, according to the specific situation and investigation surrounding environment conditions. Also want to consider. More flow meter manufacturers choose model price quote you are welcome to inquire, here are a variety of flow meter scale selection principle and method of the article details. One, the principle of flowmeter selection choose the principle of flow meter was first to deep understanding of the fundamentals of the structure of the flow meter and flow characteristics of knowledge, even at the same time, according to the specific situation and investigation surrounding environment conditions. Also want to consider the economic factors. In general, the main choice from the following five aspects: (1) meter performance requirements; (2) flow characteristics; 3. Installation requirements; (4) environmental conditions; The price of 5 meter. 1, the performance requirements of flowmeter flowmeter performance mainly includes: measuring flow ( The instantaneous flow) (or total The cumulative flow) ; Accuracy requirements; Repeatability; Linearity; Flow range and scope; The pressure loss; Output signal characteristics and the response time of the flowmeter, etc. ( 1) Measuring flow or total flow measurement includes two kinds, namely the instantaneous flow and cumulative flow, such as the transfer station pipeline crude oil belongs to trade or ratio of petrochemical pipeline for continuous production or the process of the production process control and so on need to measure total, or by observation of instantaneous flow rate. In some workplaces to control flow is equipped with the instantaneous flow measurement. Therefore, to undertake choosing according to the needs of field measurement. Some meter such as volumetric flowmeter, turbine flowmeter, etc. , its measurement principle is based on mechanical counting or pulse frequency, total output directly by its high accuracy, suitable for measuring the total, if equipped with the corresponding transmission device can also be output flow. Electromagnetic flowmeter, ultrasonic flowmeter based on measurement of fluid velocity of flow is deduced, the response is fast, suitable for process control, if match with integrating function also can get the total. ( 2) The provisions of the accuracy of flowmeter accuracy level is within the scope of a certain flow, if used in a specific condition or the flow of the narrow scope, for example, change only in a small scope, its measurement accuracy is higher than specified level of accuracy. Such as turbine flowmeter metering of the oil barrel distribution, under the condition of the valve is fully open to use, basic constant flow, its accuracy may be from zero. Level 5 to 0. 25. Accounting for trade, storage and transportation and material balance if required measurement accuracy is high, should consider the durability of the accuracy of measurement, the flowmeter is commonly used in the above case, the accuracy of grade of 0. Level 2. In the workplace is typically the site equipped with metrology standard equipment ( Such as the volume tube) The flowmeter to use online detection. Tense in recent years because of the crude oil and the high requirements for crude oil metering unit, put forward implement coefficient of crude oil metering transition, namely except for flow meter once every six months after the cycle test, trade transfer both sides talks things over every 1 or 2 months for flowmeter calibration flow coefficient is determined, according to the daily flowmeter measurement data with flowmeter to handover flow coefficient to calculate the data, in order to improve the accuracy of flow meter, also known as the zero error of transition. Accuracy degree is generally determined according to zui large margin of error of the meter. The factory provide prospectus of flowmeter are given. It is important to note that the percentage of error is refers to the relative error or reference error. Relative error of measured values, the percentage of commonly used & other; % R” Said. Reference error is refers to the percentage of measuring upper limit or range, commonly used & other; % FS” 。 Many manufacturers did not indicate the specification. For example, flow meter is commonly used reference error, error of electromagnetic flowmeter in some models also have use reference. Meter if not simply measuring the total, but the application in the fluid flow control system, the detection of flowmeter accuracy should be determined as required by the control accuracy of the whole system. Because of the whole system not only has the traffic detection error, also contains a signal transmission, control and operation of error and various influencing factors.

To that end, Beijing Sincerity Automatic Equipment Co., Ltd has successfully built a solid foundation and infrastructure for mass flow meter manufacturing.

Beijing Sincerity Automatic Equipment Co., Ltd will make a healthy profit for its owners and provide a rewarding work environment for its employees.

Beijing Sincerity Automatic Equipment Co., Ltd must adopts new technology and internal procedures to increase responsiveness and mitigate costs going forward.

The first machine to produce electromagnetic flow meter slurry, the coriolis density meter mass flow meter was invented in rosemount vortex flow meter in u shape coriolis mass flow meter by digital fork density meter and was subsequently improved.

It is never too late to have a new mindset and to get things moving in the right direction. Choose Beijing Sincerity Automatic Equipment Co., Ltd to be your quality provider.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect