loading

Sincerity Group | Coriolis flow meter manufacturers| 


Which flowmeter is more suitable for the measurement of water?

Abstract: which flowmeter is more suitable for the measurement of water? Information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Water is indispensable to our life living resources, is also indispensable to all enterprises of water resources. There are different types of the same kind of water, such as sewage, water, ammonia water, fire water, air-conditioning circulating water, water, hot water, cooling water, waste water, irrigation water, mineral water, etc. To use. More flow meter manufacturers choose model price quote you are welcome to inquire, here is what flowmeter is more suitable for measuring water? The article details. Water is the most common type of liquid medium, when we are in the selection of level gauge, usually the first factor to consider is the type of medium, the electromagnetic flowmeter is the most commonly used in flow measurement meter. Water is indispensable to our life living resources, is also indispensable to all enterprises of water resources. There are different types of the same kind of water, such as industrial and civil water and sewage, industrial ammonia, fire water, water, industrial circulating water, hot water, cooling water, chemical waste water, agricultural irrigation water, mineral water, etc. The user should ask what kind of flowmeter is more suitable for so many different waters. At present, the electromagnetic flowmeter is widely used in measurement of water flow, are excellent flow meter for measuring water flow of products. Electromagnetic flowmeter is widely used for measuring the water. Measurement in water engineering, in the practical application of electromagnetic flowmeter can run normally and accurate measurements, and properly installed grounding is an extremely important link. A, the importance of grounding potential as weak electromagnetic flowmeter measurement, need to eliminate all external disturbance can be measured accurately, so a good grounding is a necessary condition of water meter. Generally, grounding is through the sensor in the ring or internal electrode and the grounding connection of pipe system. 1. When electromagnetic flow meter installed in the path of the grounding of metal by water flow transmitter on the earthing terminal to realize the potential balance system, namely through the cross-sectional area of not less than 6 was the copper wire connected to the earthing terminal. 2. When electromagnetic flow meter installed in the path of the grounding of metal pipe, two flange by cross-sectional area for at least six was the copper wire is connected to the pipe flange and grounding; Connect the transmitter or a sensor junction box to the earthing terminal, in order to realize the potential balance system. 3. When the electromagnetic flowmeter is installed on the plastic pipe or pipes with insulating lining, by increasing the ground loop to realize the system potential balance, grounding ring by cross-sectional area for at least six was the copper wire is connected to the earthing terminal. 4. If special site environment, may require the manufacturer to order three electrodes, one of which is a grounding electrode, so that we can directly from the pipe internal implementation grounded. Second, the different of straight pipe water demand in order to guarantee the normal operation of the electromagnetic flowmeter, reduce the measuring error, electromagnetic flowmeter should meet the requirements of a straight pipe before and after. According to JJG 1033 - The electromagnetic flowmeter verification regulation of 2007 test standard requirements, usually straight pipe should be up to 10 days before the straight pipe should be reached after 5 days; According to the site construction work experience, in most applications, the different water meter straight before period of not less than five days, after the straight pipe not less than three days. Three, different installed position of water points for attention in general, electromagnetic flow timing design should pay special attention to the following: 1. Electromagnetic flowmeter should be installed in the location of the catheter may at any time is full of liquid measurement, in order to prevent the pointer caused by measuring no liquid in the pipe is not zero. Optimization, its vertical installation when liquid flows through the electrode to reduce the error due to the bubble on the electrode. 2. When there is gas buildup of electromagnetic flowmeter measurement tube or bubbles, the measurement error will increase, so it is necessary to avoid high in pipe installation of electromagnetic flowmeter sensor. 3. Water flow automatically, so from the bottom up vertically mounted inlet is correct. If from the bottom up wrong, will not only to the pipeline are not satisfied, will seriously affect the measuring precision of water. Four. The comparison of right and wrong installation quality is the premise, the installation is the key, preventive measures is the guarantee. We use a make users feel more intuitive. Electromagnetic flowmeter in flow measurement in the field of have gained wide recognition in the market, choose the high quality of the brand is the guarantee of long-term operation of water measurement, we focus the electromagnetic flowmeter industry ten years, is refers to the trust of the flowmeter you supply manufacturers, look forward to in the field of water flow and other liquid gas medium flow measurement service for you. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.

To that end, Beijing Sincerity Automatic Equipment Co., Ltd has successfully built a solid foundation and infrastructure for mass flow meter manufacturing.

Sincerity provides supreme quality and ultimate using experience.To know in detail about the prices please visit Sincerity Flow Meter.

mass flow meter are raising the stakes of social marketing, but they also ease the sales process by providing ways for low flow turbine flow meter to effectively interact with customers.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect