Abstract: metal tube rotameter scale installation time remind information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. 1, flow meter must be installed vertically, the current body from bottom to top through the flowmeter, import and export ensures have five times the diameter of straight pipe section, for the new installation of pipeline, flow meter before installing pipes should be rinsed clean. 2, for ease of maintenance and replacement flowmeter, in the instrument. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a metal tube rotameter scale installation time remind article details. 1, flow meter must be installed vertically, the current body from bottom to top through the flowmeter, import and export ensures have five times the diameter of straight pipe section, for the new installation of pipeline, flow meter before installing pipes should be rinsed clean. 2, for ease of maintenance and replacement flowmeter, the instrument need to take the bypass pipe during installation. 3, in the upstream flow meters shall be installed valves, at 5 ~ 10 meter diameter downstream flow control valve. For small diameter instrument in the upstream filter should be installed, and if the measured medium containing magnetic materials, magnetic filters should be installed in front of the meter. 4, when measured medium is dirty, should be timely cleaning tube to float. 5, metal tube rotameter measurement accuracy in general to 2. Level 5, when demand higher measurement accuracy, unfavorable choose metal rotameter. 6, import and export is not straight Angle metal flow meter, used for the liquid note gaiden float displacement of extended casing residual air, must be the row; If the liquid contains tiny bubbles flow easy to accumulate in the casing, exhaust your more regularly. That are more important for small instrument, otherwise affect flow value significantly. 7, with a liquid crystal display instrument to prevent sun point-blank, as far as possible so as not to reduce the service life of the LCD 8, avoid vibration. Including pipe external and internal causes of vibration 9, metal tube rotameter for more than one instrument installation or dense carbon steel piping through the instrument near to stay above 100 mm distance meter, avoiding interference magnetic field. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd is one of the world’s leading and most-trusted suppliers to the relevant markets.
Beijing Sincerity Automatic Equipment Co., Ltd offers a vast array of , and for all tastes and styles. When you want to kick your electromagnetic flow meter slurry up a notch, you want Sincerity Flow Meter!
With innovative technology, our professionals can spend more time focused on strategies that will improve mass flow meter’s quality and deliver a more positive customers experience.
It's the consistent experience that builds trust and loyalty. Creating a personality and platform that is scalable will allow you to evolve mass flow meter with your consumers.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com