loading

Sincerity Group | Coriolis flow meter manufacturers| 


What should be paid attention to when the vortex flow meter is used for steam measurement

Abstract: What information should be paid attention to when the vortex flowmeter is used for steam measurement? What should be paid attention to when the vortex flowmeter is used for steam measurement? Steam is divided into saturated steam and superheated steam. Generally speaking, the manufacturer of vortex flowmeter will give a table of the mass flow range of saturated and superheated steam for user selection in order to determine the size of the caliber. . More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details of what should be paid attention to when using vortex flowmeters for steam measurement. What should be paid attention to when the vortex flowmeter is used for steam measurement? Steam is divided into saturated steam and superheated steam. Generally speaking, the manufacturer of vortex flowmeter will give a table of saturated and superheated steam mass flow range for users to select, so as to determine the size of the caliber. For superheated steam, temperature and pressure compensation is required, and electromagnetic flowmeter only needs temperature or pressure compensation for saturated steam in the true sense. When measuring, check the density table according to the temperature and pressure to obtain the required mass flow. In the actual measurement, due to the change of working conditions, both saturated steam and superheated steam may deviate from the original design state, which makes the relationship between the density of steam temperature and pressure usually changed, which affects the measurement accuracy. 1. In the flow calculator, the mass flow rate of superheated steam can be calculated according to the temperature and pressure of the superheated steam. However, when the superheated steam is transported over a long distance, or due to improper pipeline insulation measures, the temperature is often lost due to heat. The reduction makes it enter the critical saturation state from the superheated state, and even part of the steam condenses and undergoes a phase change and becomes water droplets, which becomes wet saturated steam (supersaturated steam). The output of the vortex flowmeter is only proportional to the flow velocity of the fluid flowing through the measuring tube. When measuring the humidity and saturated steam, the influence of water droplets on the output of the vortex flowmeter is negligible, so it can be considered that the output of the vortex flowmeter is completely determined by Wetting is caused by the dry part (saturated part) of each steam, and the density of the dry part can be accurately detected according to pressure compensation or temperature compensation. During steam measurement, if the two parties agree to settle the fee according to the dry part of the steam and no charge for the condensate water, the effect of the phase change on the measurement is negligible and can be ignored; if the condensate water is also charged as the steam, the measurement result of the vortex flowmeter is low. 2. Wet saturated steam When the vortex flowmeter is installed in the pressure reducing valve, the wet saturated steam is suddenly decompressed by a large amount, the fluid expands adiabatically, the water droplets partially evaporate, and at the same time absorbs the heat of vaporization from the liquid phase and the vapor phase, so that the steam The temperature of the liquid phase is reduced. If the temperature is not reduced much or the humidity is high before evaporation, the temperature will be rapidly reduced to the saturation temperature corresponding to the new pressure, and a new equilibrium will be established. At this time, the steam is still saturated steam. If the pressure decreases If it is too much or the humidity is low before evaporation, the temperature will still be higher than the saturation temperature corresponding to the new pressure after the temperature is lowered due to the evaporation of water droplets, and the steam will become superheated steam. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'What should be paid attention to when the vortex flow meter is used for steam measurement'

These mass flow meter tuning fork liquid density meter are meant to serve as a guide for business owners on how to both identify potential opportunities for transformative innovation and how to adapt to the constantly changing technologies of today.

Now you can enjoy endress hauser ultrasonic flow meter with Beijing Sincerity Automatic Equipment Co., Ltd's latest collection of endress hauser coriolis mass flow meter mass flow meter products. Do visit now, at Sincerity Flow Meter.

The low flow turbine flow meter mass flow meter has significantly numerous benefits over other v shape coriolis mass flow meter systems, which makes it first choice for vortex flow meter manufacturer.

Oftentimes for Beijing Sincerity Automatic Equipment Co., Ltd, this means look for the impact. Giving people something to believe in, that emotional connection, that's what mass flow meter.

Choose the right platform for selling mass flow meter and we'll reach the right customers. But if we have the right idea in the wrong platform, that still adds up to the wrong idea.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect