loading

Sincerity Group | Coriolis flow meter manufacturers| 

What scale vortex precession flowmeter installation requirements and use?

by:Sincerity Group     2021-01-25
Abstract: what scale vortex precession flowmeter installation requirements and use? Information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Vortex precession flowmeter integrating flow, temperature and pressure detection function, and can automatically compensate for temperature, pressure, compression factor, such as petroleum, chemical, electric power, metallurgy industry ideal instrument used in the measurement of gas. Precession vortex flowmeter collector. More flow meter manufacturers choose model price quote you are welcome to inquire, here is what scale vortex precession flowmeter installation requirements and use the matters needing attention? The article details. Vortex precession flowmeter integrating flow, temperature and pressure detection function, and can automatically compensate for temperature, pressure, compression factor, such as petroleum, chemical, electric power, metallurgy industry ideal instrument used in the measurement of gas. Vortex precession flowmeter flow sensor, microprocessor, pressure, temperature sensor, adopt built-in combination, make the structure more compact, can directly measure the fluid flow, pressure and temperature, and automatic tracking compensation and real-time compression factor correction. Introduce to you the following installation requirements and use of the vortex precession flowmeter notice: 1. Vortex precession flowmeter flowmeter installation, it is strictly prohibited in the import and export directly to where the flange welding, so as not to burn out flowmeter internal parts. For the new pipe must be cleaned after installation or maintenance, can remove the impurities in the pipeline before the installation of flow meter. Meter should be installed in easy maintenance, strong electromagnetic interference, strong mechanical vibration and the influence of thermal radiation place; Flowmeter is unfavorable with frequent interruptions in the flow and strong pulsating flow or pressure pulsation occasions; Meter outdoor installation, should be the upper cover, to prevent rain water immersion and strong sunlight affect the service life of the meter; Can install at any Angle of the flow meter, the flow of fluid shall conform to the flow direction of logo on the meter; In pipeline construction, should consider to install expansion tube or bellows, lest cause serious tension or the meter; Meter shall be installed with coaxial pipe, and prevent the seal and butter into the pipe inner cavity; When external power is adopted, the meter must be reliable grounding, may not be common ground with heavy current system, the pipe installation or maintenance, can't leave the ground and flowmeter lap welding system. In order not to affect the normal fluid transmission and easy to maintain, requests the shown in figure 4 by-pass pipe installation, and ensure the former & ge; After 3 dn, & ge; 1 dn straight section 2. Installation note sensor according to the flow marks can be tilted in vertical, horizontal, or any location on the installation; When the line is longer or close from the vibration source, support should be installed at upstream or downstream of flowmeter, in order to eliminate the influence of the pipeline vibration; Sensor installation location should have enough space, so that the flow meter inspection and maintenance, and shall meet the environmental requirements of flowmeter; Should avoid the disturbance of external magnetic field; When used in outdoor installation, should have cover, avoid the strong sunlight and rain erosion, affect the service life of the instrument; Pipeline pressure test, the intelligent flowmeter should be paid attention to the configured pressure pressure sensor measuring range, in order to avoid over-voltage damage pressure sensor. Installation should be paid attention to stress, the influence of upstream and downstream piping should be coaxial installation flowmeter, otherwise it will produce shear stress. The location of the installation flowmeter should consider the thickness of the sealing gasket, or install a elastic expansion joints in the downstream side. Should be clear before installation flowmeter in the pipeline welding slag and other sundry. When in operation, should slowly open flowmeter, downstream of the valve, in order to avoid air flow is too sharp and blunt bad on the moment. When the meter requires signal remote transmission, should be strictly in accordance with & other; Electrical performance & throughout; Request access to external power ( 8 ~ 24) VDC, forbidden in direct access to 220 vac or 380 vac signal output power; Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd is devoted to satisfy our customers with a wide array of the finest using experience.
Beijing Sincerity Automatic Equipment Co., Ltd is one of China's biggest providers in the following categories of products: mass flow meter, insertion ultrasonic flow meter, coriolis density meter,etc. We also welcome ODM and OEM orders, and offer the highest standards of service, the cheapest deals, and the best buying experience. Get to know us at Sincerity Flow Meter.
We studied how market-leading companies are harnessing data to reshapeBeijing Sincerity Automatic Equipment Co., Ltd, and explored how they can put data to work for us in ways that create value for our own businesses.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: