loading

Sincerity Group | Coriolis flow meter manufacturers| 


Vortex flow meter scale installation requirements

Abstract: the scale vortex flowmeter installation using the information required to be made by the excellent flow meter, flow meter production factory to provide you with quotation. Vortex street flowmeter installation requirements 1, the choice of reasonable installation location to avoid strong power equipment, high-frequency equipment, strong power switch device; To avoid the influence of high temperature heat source and the radiation source, to avoid strong vibration and strong corrosive environment and so on, at the same time to consider installation. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a scale vortex flowmeter article details installation requirements. Vortex street flowmeter installation requirements 1, the choice of reasonable installation location to avoid strong power equipment, high-frequency equipment, strong power switch device; To avoid the influence of high temperature heat source and the radiation source, to avoid strong vibration and strong corrosive environment and so on, at the same time to consider easy installation and maintenance. 2, upstream and downstream straight pipe must have enough. If the sensor installed upstream of point on the same plane has two 90. Elbow, are: straight pipe upstream & ge; 25 d, the downstream straight pipe & ge; 5 d。 If the sensor installed upstream of point in different plane has two 90. Elbow, are: straight pipe upstream & ge; 40 d, downstream straight pipe & ge; 5 d。 Regulating valve should be installed on the downstream side of the sensor outside 5 d, if must be installed in the upstream of the sensor, the sensor straight pipe upstream should be not less than 50 d, downstream should be not less than 5 d. 3, pipeline vibration reduction measures. Sensor to avoid installed in the strong vibration, transverse vibration in particular. If need to install the anti-vibration measures must be taken, respectively at the upstream and downstream of sensor 2 d piping fastening device, and vibration-proof pad. 4, are installed in horizontal pipe runs zui vortex flowmeter installation method in common use. Measuring gas flow rate, if contain a small amount of fluid in the gas being measured, the sensor should be installed in the pipeline is relatively high. Measurement of liquid flow, if the liquid contains a small amount of gas being measured, the lower part of the sensor should be installed in the pipeline. Upstream and downstream piping should be installation points and the sensor concentric, coaxial deviation should be no less than 0. 5DN。 5, the installation of sensors in a vertical pipe. Measuring gas flow rate, the sensor can be installed in vertical pipe runs, flow to the unlimited. If the measured gas containing a small amount of liquid, gas flow should be from the bottom up. Measuring the liquid flow rate, liquid flow shall be from the bottom up: it won't attach additional liquid weight on the probe. 6, selection of pressure and temperature measuring points. According to the demand of measurement should be near the sensor to measure the pressure and temperature, the pressure measuring point should be 3 - of the downstream of the sensor 5 d, temperature measuring points should be 6 - of the downstream of the sensor 8 d7, sensors in a horizontal pipe to the side. Regardless of what kind of flow measurement, the sensor can be in the upper horizontal pipeline, especially the measurement of superheat steam and saturated steam and low temperature liquid, if the condition allows zui to good use side, so the temperature of the fluid have less effect on the amplifier. 8, sensors in a horizontal pipe of inversion. Generally do not recommend using this installation method. This installation method is not applicable to measure the general gas, superheated steam. Can be used for measurement of saturated steam, high temperature suitable for measuring the liquid or frequent cleaning pipelines. When measuring high temperature steam, thermal insulation layer zui much can't more than a third of the bracket height. Above is the two-phase vortex street flowmeter to share the content of the above is all there is in this article, you are welcome to inquire me factory flowmeter selection, quotation, etc.

Sincerity is the leading manufacturer of mass flow meter and related products.

Beijing Sincerity Automatic Equipment Co., Ltd is one of China's biggest providers in the following categories of products: mass flow meter, vortex flow meter manufacturer, insertion ultrasonic flow meter,etc. We also welcome ODM and OEM orders, and offer the highest standards of service, the cheapest deals, and the best buying experience. Get to know us at Sincerity Flow Meter.

As the manufacturing procedure of mass flow meter becomes more regulated, the costs to businesses will increase and the workforce will suffer as a result.

Beijing Sincerity Automatic Equipment Co., Ltd have found that nurturing relationships with clients by welcoming them to our factory can be valuable to all parties.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect