loading

Sincerity Group | Coriolis flow meter manufacturers| 

Vortex flow meter installation conditions and points for attention

by:Sincerity Group     2022-10-03
Abstract: The installation conditions and key points of the vortex flowmeter are provided by the excellent flowmeter and flowmeter manufacturers. Vortex flowmeter Installation conditions 1. The sensor should be installed on a horizontal, vertical, inclined (liquid flow from bottom to top) pipeline with the same diameter. The upstream and downstream of the sensor should be equipped with straight pipe sections of a certain length, and the length should be consistent with the previous straight pipe section 1. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following are the details of the installation conditions and key points of the vortex flowmeter. Vortex flowmeter installation conditions 1. The sensor should be installed on a horizontal, vertical, inclined (liquid flow from bottom to top) pipeline with the same diameter. The upstream and downstream of the sensor should be equipped with straight pipe sections of a certain length. 2. The nearby pipeline where the liquid sensor is installed should be filled with the liquid to be measured. 3. The sensor should be avoided to be installed on the pipeline with strong mechanical vibration. 4. The inner diameter of the straight pipe section is as consistent as possible with the sensor diameter. If it cannot be consistent, a pipe slightly larger than the sensor diameter should be used, and the error should be≤3%, not more than 5mm. 5. When the measured medium contains a lot of impurities, a filter should be installed beyond the required length of the straight pipe section upstream of the sensor. 6. The sensor should be avoided to be installed in places with strong electromagnetic field interference, small space and inconvenient maintenance. Vortex flowmeter attention points 1. Reasonably choose the installation site and environment. Avoid strong power equipment, high frequency equipment, strong power switch equipment; avoid the influence of high temperature heat sources and radiation sources, avoid strong vibration places and strong corrosive environments, etc., and consider the convenience of installation and maintenance. 2. There must be enough straight pipe sections upstream and downstream. If there are two 90s in the same plane upstream of the sensor mounting point. Elbow, then: upstream straight pipe section≥25D, downstream straight pipe section≥5D. If there are two 90s on different planes upstream of the sensor mounting point. Elbow, then: upstream straight pipe section≥40D, downstream straight pipe section≥5D. The regulating valve should be installed beyond 5D downstream of the sensor. If it must be installed upstream of the sensor, the upstream straight pipe section of the sensor should not be less than 50D, and the downstream should not be less than 5D. 3. The piping upstream and downstream of the installation point should be concentric with the sensor, and the coaxial deviation should not be less than 0.5DN. 4. Vibration reduction measures shall be taken for the pipeline. Try to avoid installing the sensor on the pipeline with strong vibration, especially the lateral vibration. If the installation is unavoidable, vibration reduction measures must be taken, and pipe fastening devices and anti-vibration pads should be installed at the upstream and downstream 2D ​​of the sensor. 5. Installation on horizontal pipes is the most common installation method for flow sensors. When measuring gas flow, if the measured gas contains a small amount of liquid, the sensor should be installed at a higher part of the pipeline. When measuring liquid flow, if the measured liquid contains a small amount of gas, the sensor should be installed at the lower part of the pipeline. 6. Installation of sensors in vertical pipes. When measuring gas flow, the sensor can be installed on vertical pipes with unlimited flow direction. If the measured gas contains a small amount of liquid, the gas flow should be from bottom to top. When measuring liquid flow, the flow direction should be from bottom to top: this will not add extra liquid weight to the probe. 7. The sensor is installed on the side of the horizontal pipe. No matter what kind of fluid to measure, the sensor can be installed on the horizontal pipeline, especially for superheated steam, saturated steam and low temperature liquid. 8. The sensor is installed upside down in a horizontal pipe. This installation method is generally not recommended. This installation method is not suitable for measuring general gas and superheated steam. It can be used to measure saturated steam, and it is suitable for measuring high temperature liquid or when the pipeline needs to be cleaned frequently. 9. Installation of sensors on insulated pipes. When measuring high temperature steam, the insulation layer should not exceed a maximum of one-third of the height of the bracket. 10. Selection of pressure and temperature measurement points. According to the needs of measurement, when pressure and temperature need to be measured near the sensor, the pressure measurement point should be at 3-5D downstream of the sensor, and the temperature measurement point should be at 6-8D downstream of the sensor. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Vortex Flow Meter Installation Conditions and Points to Note'
If you are looking for convenient, affordable , Sincerity brings plethora of options to suit your requirements and budget both. Check Sincerity Flow Meter for more details.
Looking for someone to handle your mass flow meter electromagnetic flow meter slurry needs? Check out Sincerity Flow Meter today for more information.
Innovative technology helped us produce a strong, reliable product as mass flow meter for customers, offer superior quality and dependability to our customers, and scale at a quicker pace.
A wholesaler should have many fork density meter manufacturer based products that could help you if you have a rosemount coriolis mass flow meter problem. It is better to treat the problem early rather than have to deal with it later. Beijing Sincerity Automatic Equipment Co., Ltd is your best choice.
The best way to determine the ideal strategy of mass flow meter is to continually test and refine your selling and marketing tactics.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: