loading

Sincerity Group | Coriolis flow meter manufacturers| 


Turbine flowmeter requirements for installation environment

1. Safety The safety of the turbine flowmeter is the main consideration in the selection of the flowmeter, such as the requirements for explosion-proof performance, application in explosive hazardous environments, grouping according to atmosphere adaptability, explosive mixture classification, type of protective electrical equipment, and other safety rules or standards Select a gauge. 2. Compressive strength It is required that the shell should be able to withstand a 5-minute compressive strength test at a test pressure of 1.5 times the maximum working pressure without damage or air leakage. 3. Ambient temperature The electronic components of the instrument and some flow detection parts of the instrument will be affected by changes in the ambient temperature. 4. Environmental humidity High humidity will accelerate atmospheric corrosion and electrolytic corrosion and reduce electrical insulation, and low humidity will easily induce static electricity. Humidity problems caused by sudden changes in ambient or medium temperature. The user should anticipate the range of possible changes and check whether it will cause problems in the operation of the selected instrument. 5. Electrical interference Power cables, motors and electrical switches will all generate electromagnetic interference, which will become the source of errors. Therefore, attention should be paid to prevention or reasonable and effective grounding or shielding of interference sources. 6. Pipeline vibration Some flow meters (such as vortex flowmeters, Coriolis mass flowmeters) are susceptible to vibration interference, so it should be considered to use the pipeline after the label as a reliable support design. Pulsation snubbers can eliminate the effects of pumps and compressors, but should be installed away from vibration or pulsation. 7. Conditions of upstream and downstream pipe sections and requirements for straight pipe sections Most velocity flowmeters, including turbine flowmeters, are more or less affected by the inlet flow conditions, and a good flow velocity distribution must be ensured. Piping arrangements introduce different types of flow disturbances, the most common being velocity profile distortion and eddies. Vortex is generally caused by two or more space bends. These effects can be improved by using an appropriate length of upstream straight pipe section or installing a rectifier to ensure the stability of the flow velocity of the measured pipe section and the full pipe state. 8. Piping layout direction Some turbine flowmeters are installed horizontally and vertically, and there will be differences in measurement performance. For example, the vertical downward flow of fluid brings additional forces to the rotating components of the instrument, which can significantly affect performance, linearity or repeatability. The vertical installation of grounded flowmeters is conducive to the measurement, such as metal tube rotameters. The installation direction of most instruments is stipulated by the manufacturer and should be followed.

Wow, this sounds like a bit of a cruel question, but it is a vitally important question to ask yourself if you are struggling with your coriolis mass flow meter emerson and you would like to stop the mass flow meter problem.

Beijing Sincerity Automatic Equipment Co., Ltd plans to produce and execute four marketing seminars, one per quarter, to help business owners see success by sharing important growth strategies and hosting interactive workshops.

Beijing Sincerity Automatic Equipment Co., Ltd emphasizes our commitment to quality in our laboratory and R&D services.

Now that Beijing Sincerity Automatic Equipment Co., Ltd has become a leader in the space and have been able to scale appropriately, we are ready to expand to other cities.

Beijing Sincerity Automatic Equipment Co., Ltd needs to ensure we're resolving customer issues as quickly as possible. By doing so, it leads to positive customer experiences and brand loyalty.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect