Abstract: several reasons of turbine meter scale accuracy decline information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Turbine flowmeter has a compact structure, intuitive and clear reading, high reliability, without external power supply interference, lightning resistance, low cost, obvious advantages, widely used in petroleum, chemical industry, metallurgy, paper making industries such as measuring the volume of fluid transient flow meter and a body. More flow meter manufacturers choose model price quote you are welcome to inquire, here is some reason turbine meter scale accuracy declining article details. Turbine flowmeter has a compact structure, intuitive and clear reading, high reliability, without external power supply interference, lightning resistance, low cost, obvious advantages, widely used in petroleum, chemical industry, metallurgy, paper making industries such as measuring the volume of fluid transient flow meter and the total volume. See online, some people ask, turbine flowmeter in use process, found that the accuracy decreased, so what is the reason? Usually have some impurities in 1, the medium, to produce the wear of bearing, axis, increased the gap between, the moving parts of dynamic balance is destroyed, speed, or dirt into the gap, make motion resistance increases, speed down. All of these reasons resulting in a decrease of instrument display value, negative error, adverse to the fluid of the supplier. 2, fluid of fibrous or viscous impurities attached to the rotating part of the flowmeter, make rotational resistance increases, resulting in a decrease of instrument of the indicated value, the negative error, adverse to the fluid of the supplier. 3, fluid temperature and pressure changes may make the escape of the liquid in the pipe air or because of the pressure inside the pipeline is lower than fluid saturation vapor pressure, make part of the liquid and steam, is also likely to make out with medium pressure air is sucked into the pipe, the gas with the measured liquid, causing instrument indicated value increase, there is error, adverse to the fluid of the buyer. 4, working environment is poor, for example, the electromagnetic interference, dust, high temperature, vibration, humidity, etc. , may cause a malfunction or failure of turbine flow sensor, the direct cause of turbine flowmeter, of error of error is positive or negative, may not be obvious, may complete failure. For the above phenomenon, the more serious when, can find problems from the comparison the working state of the process, easy to take corresponding measures. But, in the early part of the problem, don't take special measures can't found the problem. Turbine flowmeter maintenance should pay attention to the following: 1, when using, should maintain the cleanness of measured medium, does not contain impurities such as fiber and particles. 2, turbine flow sensor, at the beginning of the use should be to slow sensor with medium, and then open the outlet valve ( The valve should be installed in the back-end flow meters) , the sensor is in a state of no medium is strictly prohibited by the high velocity impact. 3, the maintenance period of turbine flow sensor is usually half a year. Maintenance when cleaning, please note that you are the measuring chamber of damaged parts, especially in the impeller. Please watch the orientation and the position of the impeller when assembling. 4, turbine flow sensor need not when, should be clean inside medium, dry and after on both ends of the sensor and protective cover, prevent dirt to enter, and then placed in a dry place preservation. 5, with the filter should be cleaned regularly, need not when should clean the internal medium, as well as sensors, dustproof set, placed in a dry place preservation. 6, in front of the sensor installation, with his mouth or hand wheel, make its rapid rotation observations have showed that sensor installation again when have shown. If no display, should check the relevant parts, troubleshooting. Into abundant flow meter is a professional supplier of flowmeter, the production of various kinds of flowmeter types: glass rotor flowmeter, metal tube float flowmeter, electromagnetic flowmeter, turbine flowmeter, vortex street of domestic * glass rotameter instrument sales. Buy flowmeter, looking for professional manufacturers, flow meter. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd specializes in undertaking corporate offers to cater the needs of different companies.
As a global mass flow meter company, we take on some of the world’s biggest mass flow meter challenges. Beijing Sincerity Automatic Equipment Co., Ltd have a whole series of vortex flow meter manufacturer mass flow meter that can solve your mass flow meter problem in an effective manner. Check it at Sincerity Flow Meter.
By investing in an ethical supply chain, Beijing Sincerity Automatic Equipment Co., Ltd position ourselves to engage with a driven, engaged customer base.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com