loading

Sincerity Group | Coriolis flow meter manufacturers| 


Thermal type gas mass flowmeter is analysed scale installation and signal and blast aeration

Abstract: the thermal type gas mass flowmeter is analysed scale installation and signal and blast aeration information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Thermal type gas mass flowmeter and reliable measurement accuracy and repeatability, and the scene of free maintenance, make the product has an important role in the cascade control system is becoming more and more obvious. Its successful use not only to improve the performance of the control system, also for the quality of sewage treatment. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a thermal type gas mass flowmeter is analysed scale installation and signal and blast aeration article details. Thermal type gas mass flowmeter and reliable measurement accuracy and repeatability, and the scene of free maintenance, make the product has an important role in the cascade control system is becoming more and more obvious. Its successful use not only to improve the performance of the control system, also provides important guarantee for the sewage treatment standard quality. The stand or fall of thermal type gas mass flowmeter using effect depends on the correct installation and signal connections. ST98 output current signal is active 4 ~ 20 mA, in order to connect with the existing control system, need to add signal converter is converted to a passive 4 ~ 20 mA standard signal, as shown in figure 3. Air duct by ST98 air flow measurement, in addition to the scene in situ show that instantaneous/cumulative flow, 4 ~ 20 mA output signal receiving, processing after converter by PLC, after the comparison with the given value which can adjust the air flow. With air volume adjustment, can realize cascade control aeration system, to better meet the requirements of automatic adjustment of dissolved oxygen. Sewage treatment plant aeration pool of dissolved oxygen (do) is a key parameter of wastewater treatment process, to control in a certain concentration. Excess aeration can increase energy consumption, increase the cost of sewage treatment, insufficient aeration can make drop low dissolved oxygen, is not conducive to microbial growth in water, zui will affect the effect of sewage treatment. Dissolved oxygen concentration and water quality, temperature, pressure, air and so on has a very close relationship, when the outside conditions change, dissolved oxygen concentration has been changed. In the above factors, only air can be artificially controlled and so on with dissolved oxygen as the feedback loop thermal type gas mass flowmeter in the closed loop control system, the introduction of air volume adjustment, implementation of dissolved oxygen, cascade control, can make better effect, as shown in figure 4. Can be seen from the diagram, the dissolved oxygen (do) ( DO) Regulator and air conditioner, concatenated DO the output of the controller is as given value of air conditioner, controlled by the air conditioner regulator action. DO as the main to adjust parameters, it is a process to control indicators. Air is the deputy to adjust parameters, it is to stabilize the tone and introducing auxiliary parameters. DO regulator according to the main parameters and process the deviation of a given value of work, its output as the given value of the air conditioner, DO regulator plays a leading role in the system. Air conditioner according to the flow that a pair of parameters and the DO regulator of the deviation of a given value, the output control regulator directly. Under normal circumstances, assuming that feed water quantity, water quality, water temperature and other conditions are the same, blower outlet pressure, the air is the same, oxygen consumption rate and oxygen filling rate basic balance, dissolved oxygen concentration on the given value. When some factors change destroyed the balance, regulator that is working. ( 1) Changed due to some reason the flow of air duct, flowmeter measurement to this change, response to the input end of the flow regulator, the air conditioner to adjust in time, change the valve opening, if the change is small, after the class, before the changes did not affect the parameters of the dissolved oxygen was overcome. If the change is bigger, because most of the air volume link overcome, then by large loop further adjustment, to eliminate the change, the impact on restoring the dissolved oxygen (do) to the given value. ( 2) Due to the aeration tank of water quantity and water quality changed, destroyed the original balance, also resulted in the changes of dissolved oxygen aeration, two stage regulator works at the same time, speed up the adjustment. ( 3) If this change also resulted in the changes of dissolved oxygen, traffic, at the same time, the direction of two regulator control of the regulating valve in the same direction, speed up the adjustment function, make the lead role, is helpful for the improvement of the regulating quality. The change in the opposite direction, the stability of dissolved oxygen must guarantee, work must be conducted in accordance with the requirements of the dissolved oxygen, because the two thermal type gas mass flowmeter regulator in the opposite direction, offset, deviation greatly decreases, and the regulator as long as the slightest move, can make the system balance. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.

Beijing Sincerity Automatic Equipment Co., Ltd thinks that that firms can avoid the artificial choice between quantitative and qualitative risk management, allowing both to play important roles in surfacing and assessing risks.

If you follow these straightforward steps you can keep your endress hauser coriolis mass flow meter low flow turbine flow meter. I think this article will help you make a wise decision on choosing the right .

In terms of mass flow meter, why is it different than other production? How does it fit a true need or desire for your requires? Is it simple to use? Make life easier?

There are so many factors that businesses have to weigh when producing mass flow meter, and we are not going to pretend to grasp all of them.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect