Abstract: the use of electromagnetic flowmeter scale late repair and maintenance of the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Due to the use of the intelligent electromagnetic flowmeter is ferrari's principle of electromagnetic induction, so the correct according to the nature of the medium to the selection and installation of science, generally the failure rate is very low, but also can't avoid some use the operating error caused. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the use of electromagnetic flowmeter scale late repair and maintain article details. Due to the use of the intelligent electromagnetic flowmeter is ferrari's principle of electromagnetic induction, so the correct according to the nature of the medium to the selection and installation of science, generally the failure rate is very low, but also can't avoid using operational error caused some damage. Here we summarize the work experience, for some common faults in the intelligent electromagnetic flowmeter in daily use give some solution 1, header LCD screen no display, no signal output failure analysis: 1). And check whether the power supply is connected or the power supply circuit fault 2) Good, check whether the output signal or wiring loose; 3) , flow meter, measuring pipeline and medium grounding is not reliable; 4) , measuring medium not completely full of pipeline; 5) And electrode surface oxide or attachments, cleaning electrode; 6) , measuring circuit fault 2, liquid crystal display is not clear, output rock failure analysis: 1) , adjust potentiometer & lsquo; 1 w3 ' Clockwise to increase the contrast; 2) , fluid itself is passive or pulse; 3) , pipes, not filled with liquid or liquid containing bubbles; 4) And outside electromagnetic interference; 5) And liquid physical properties ( Conductivity uneven or containing impurities) 6) And electrode contaminated or corrosion; 7) , flow meter, measuring pipeline and medium grounding is not reliable; 3, unstable zero failure analysis; 1) , pipes, not filled with liquid or liquid containing bubbles; 2) There is small, the pipe flow of 3) Imperfect, grounding, external electromagnetic clutter interference; 4) And liquid physical properties ( Conductivity uneven or containing impurities) ; 5) , signal circuit insulation falling; 4, header display measured values do not tally with the actual value failure analysis: 1) , sensor value is not correct; 2) And sensor installation position is not correct, or liquid containing bubbles under pipe; 3) Length of straight pipe upstream or downstream, sensor is insufficient; 4) , the measuring tube containing other affect measuring branch; 5) Good, unprocessed signal cable or cable insulation decline in use process; 5, the output signal full value failure analysis: 1) Unicom, detecting sensor electrodes to see if there is liquid; 2) , detection cable is disconnected or wiring error; 3) , after the instrument is not electrical isolation or error setting above is all there is in this article, you are welcome to inquire me factory flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd is the largest manufacturer of mass flow meter, which is one of the best product manufactured from us.
Make your endress hauser ultrasonic flow meter coriolis mass flow meter emerson. Invest in professional mass flow meter services. For more info, check out Sincerity Flow Meter.
Beijing Sincerity Automatic Equipment Co., Ltd has never compromised on the quality and the services provided to the customer.
Advanced technology and manufacturing equipment has enhanced the core quality of mass flow meter.
Beijing Sincerity Automatic Equipment Co., Ltd can assure that it is one of the best products in the market at present.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com