loading

Sincerity Group | Coriolis flow meter manufacturers| 

The understanding of the rotameter scale and error solution

by:Sincerity Group     2020-11-11
Abstract: the understanding of the rotameter scale and error solution information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Flow meter is used to measure the liquid or the linear, nonlinear, mass or volume of the gas flow of the instrument. Good flowmeter selection is based on a clear understanding of specific application requirements. Therefore, to take the time to fully evaluate the nature of the fluid and the whole installation process. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the understanding of the rotameter scale and error solution article details. Flow meter is used to measure the liquid or the linear, nonlinear, mass or volume of the gas flow of the instrument. Good flowmeter selection is based on a clear understanding of specific application requirements. Therefore, to take the time to fully evaluate the nature of the fluid and the whole installation process. Choose flow timing, familiarity, and they should consider the specific factory personnel experience of calibration and maintenance, spare parts supply ability and intangible factors such as average failure time interval. It is recommended to take these steps to install again after cost calculation. Zui one of common flow measurement error is to reverse the order of these steps are: not to select sensors can work normally, but trying to find a reason to use cheaper products. The low purchase may be a zui problems of expensive facilities: a, rotor flowmeter measurement error: 1. Influence on gas medium due to temperature and pressure, and recommended way to obtain the real flow of temperature, pressure compensation. 2. Due to long-term use of multiple factors flow meter sensing and pipeline vibration, magnetic steel, Pointers and counterweight, rotating magnetic steel parts loose, caused the error. Solution: can use first hand push pointer to verify. First of all, the position of the pointer on the RP to see if the output is 4 ma, flow display is 0%, and in turn according to the calibration for validation. If found, can be adjusted to place parts. Generally require professional personnel adjustment, otherwise it will cause the loss position, need to return to factory. 3. Installation does not conform to the requirements: for vertical installation to keep vertical rotor flowmeter, dip Angle is not more than 20 degrees; For horizontal rotor flowmeter must keep level, tilt Angle is not more than 20 degrees; Rotameter around 100 mm space may not be a ferromagnetic objects. To stay away from the valve installation position process pipeline diameter changes, pump discharge, corner, etc. Keep straight pipe before 5 d after 250 mm. 4. The density of liquid medium larger changes is also a cause of error. Because the instrument before calibration, it will be medium conversion, according to the density of users give converted to calibration status of water flow in calibration, so if the change of medium density is bigger, can cause very big error of measurement. Solution can be change after medium density into the formula of the conversion error correction coefficient, then flow meter to measure flow rate multiplied by the coefficient for the real traffic. Second, the rotor flow meter pointer jitter: 1. Due to severe pointer jitter: medium pulse, pressure instability or users are given the gas pressure, temperature and flow of the operating state does not accord with the actual state of the rotor flowmeter, has a bigger difference caused by the rotor flow meter range. 2. Slight pointer jitter: generally caused by fluctuations in medium. Can be used to increase the damping ways to overcome. 3. Moderate pointer jitter: generally caused by medium flow state. Is often caused by unstable operating pressure of medium for gas. Can use voltage or current regulator devices to overcome or increase the air damping rotor flowmeter. Three, rotor flowmeter cursor to a location to be not moved, the main reason is that the rotor flow meter rotor. Generally due to rotor flowmeter open valve too fast when using, makes the rotor fast upward shock stop, stop deformation caused rotor card to death. But does not rule out due to the rotor guide bar with different heart stop ring, causing rotor. Processing instrument can be removed, the deformation of plastic surgery to stop off, and check whether with guide bar work, such as different heart can be calibrated, then the rotor installed, push the rotor, feeling the rotor unimpeded card can be up and down, in addition, the rotor flowmeter installation must be vertical or horizontal installation, cannot tilt, otherwise easy to cause the card table, and also brings to the measurement error. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
is frequently used by people in daily life since it can improve coriolis density meter and electromagnetic flow meter slurry.
Try out rosemount coriolis mass flow meter mass flow meter to beautify your insertion ultrasonic flow meter. Visit Sincerity Flow Meter to get your dreaming at a favorable price.
Beijing Sincerity Automatic Equipment Co., Ltd's core technology of mass flow meter enables us to understand and utilize in a right way.
The trend toward using rosemount vortex flow meter mass flow meter to ease coriolis mass flow meter emerson, once established, soon extended into such additional fields as v shape coriolis mass flow meter and endress hauser coriolis mass flow meter.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: