loading

Sincerity Group | Coriolis flow meter manufacturers| 


The error analysis of the electromagnetic flowmeter in scale use instance

Abstract: the electromagnetic flow meter scale using error analysis in the examples of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Electromagnetic flowmeter has many advantages, but improper selection, installation and use, will cause the error increases, the value is not stable, and even the table body is damaged, will now be produced in the operation of the electromagnetic flowmeter in a brief analysis of error. 1, the tube liquid underfill. Due to the. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the electromagnetic flowmeter scale using instance article details in the error analysis. Electromagnetic flowmeter has many advantages, but improper selection, installation and use, will cause the error increases, the value is not stable, and even the table body is damaged, will now be produced in the operation of the electromagnetic flowmeter in a brief analysis of error. 1, the tube liquid underfill. Due to lack of back pressure or flow sensor installation location, leading to the measuring tube filled with liquid to level of failure phenomenon due to not full and flow conditions have different performance. If a small amount of gas in pipe duct in stratified flow and wave flow, fault phenomenon characterized by error increases, the flow measurement values do not tally with the actual value; If flow is the flow of air bubbles or plug flow, fault phenomenon in addition to the measured values do not tally with the actual value, will be output by gas phase instantaneous covered electrode surface rock; If the gas phase stratified flow in horizontal pipeline flow cross-section part increases, the liquid under the degree of pipe increases, also can appear the output, if the liquid under line situation is serious, so that the electrode surface is below the output will appear super full phenomenon. Example 1 a shipyard has a DN80mm electromagnetic flowmeter measurement of water flow, operation personnel flow to zero after close the valve, the output instead of to achieve full value. Spot checks found that only a short tube, sensor downstream water directly into the atmosphere, the cut-off valve is installed in the upstream of sensor and sensor tube after all water emptying valve is closed. Adapted to the valve position 2, the fault is solved. This kind of the cause of the problem in the case of the factory after-sales service is often encounter, when the error in the engineering design. 2, the solid phase in the liquid. Powder, particles, or fiber in the liquid to solid, the possible fault; 1) slurry noise; (2) electrode surface defiled; (3) insulation sediments or sedimentary cover or lining electrode; (4) the lining by wear or by sediments, narrow flow cross-section. Example 2 conductive deposits short-circuit effect. Electromagnetic flow sensor measurement of pipe insulation lining if deposited conductive material, traffic signals will be short circuit and make the instrument failure. Because of conductive material is sedimentary gradually, this kind of failure usually will not appear in the debugging stage, and to run after a period of time. A diesel engine factory electrolytic process test device, cutting tool workshop with DN80mm instrument measurement and control of saturated salt electrolyte flow for zui better cutting efficiency. At first the meter running, continuous use 2 months later, feel the flow display value more and more small, until the traffic signal is close to zero. On-site inspection, found that the insulation layer deposits a layer of yellow rust, the surface is wiped clean after the meter running. Yellow rust layer is caused by a large number of iron oxide deposition in the electrolyte. This example is a run-time failure, although not see more failures, but if black metal pipeline corrosion is serious, the sedimentary rust layer, also can have the effect of short circuit. Who started running normal, over time, the flow shows more and more small, should be analyzed with the possibility of such failure. 3, possible crystallization liquid, electromagnetic flowmeter should be used carefully. Some easy crystallization chemical material in normal under the condition of normal temperature measurement, as a result of the transmission fluid conduit has good thermal insulation, the insulation not crystallization at work, but difficult to implement electromagnetic flow sensor measurement of tube, thermal insulation, therefore, when the fluid flows through the measuring tube is caused by cooling wall in a layer of solids. Due to switch to other principle of crystallization of the flowmeter measurement also exists, so in the case of no other better way, can choose a kind of measuring tube length is very short & other Ring & throughout; ( oring) Electromagnetic flow sensor, and the flow meter of upstream pipe thermal insulation shall be strengthened. On the pipeline connection methods, considering flow sensor tear open outfit is convenient, when once the crystallization can easily remove the maintenance. Example 3 electromagnetic flowmeter can't work normally caused by liquid crystal examples are not uncommon. Hunan, for example, some smelters to install a batch of electromagnetic flowmeter measurement solution flow rate, because of electromagnetic flowmeter sensor measuring tube is difficult to implement the thermal insulation, the lining after a few weeks and electrode on it with a layer of crystal, leading to the signal source resistance become large, said value disorder. Because this batch of larger diameter electromagnetic flowmeter, frequent unbearable unpick and wash, so after zui or switch to open channel flow meter. 4, the problems caused by improper selection and grounding electrode ring material. Caused by material and does not match the measured medium fault of electromagnetic flowmeter with parts in contact with the medium and grounding electrode, the matching misconduct in addition to the corrosion problem, as long as it is electrode surface effect. Surface effect should be: (1) chemical reaction ( Membrane surface blunt words, etc. ) ; (2) and electrochemical polarization ( Produce potential) ; (3) catalysis ( Electrode surface generating aerosol, etc. ) 。 Grounding ring also have these effects, but the influence degree. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.

The average consumer is always looking for ways to save money while finding out solutions, is designed for killing two birds with one stone, providing a perfect solution to mass flow meter problems.

Beijing Sincerity Automatic Equipment Co., Ltd has had manufacturing experience for over electromagnetic flow meter slurry years. She currently runs a website where they sell . You can visit her site at Sincerity Flow Meter.

Loyalty programs provide an opportunity to learn the preferences of customers and design communication strategies that will resonate with mass flow meter.

mass flow meter are less complex compared with vortex flow meter manufacturer.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect