The environmental factors that affect the measurement of mass flowmeters are as follows: 1. The influence of fluid pressure First consider that the fluid pressure should not exceed the specified working pressure, and then consider the degree of influence of static pressure changes. Pressure changes affect the degree of tube tension and the extent of the Budden effect, as well as the original zero offset that disrupts the asymmetry of the tube. Although the instrument constant variation and zero drift are very small, the influence on the high-precision instrument cannot be ignored when there is a large difference between the pressure used and the calibration. Small-diameter instruments have a large wall thickness and pipe-diameter ratio, and the influence is small; large-diameter instruments have a large wall thickness and pipe-diameter ratio. 2. Effect of fluid density The change of fluid density changes the quality of the flow measurement system, thus changing the balance of the flow sensor and causing zero point offset. If a specific liquid is measured, as long as it is zeroed under the condition of the actual liquid density, the density will not change much during use, and generally there is no problem. However, when measuring several liquids with large density differences on a pipe, it will bring additional errors of zero point changes. 3. Influence of fluid viscosity Rosemount's Coriolis mass flowmeter CMF can measure a wide range of liquid viscosity and exhibit good measurement performance. Although there are reports that viscosity affects measurement accuracy, there are few experimental data. Fluid viscosity changes the damping characteristics of the system, which affects zero bias: at low flow, it affects the flow measurement to a certain extent. 4. Influence of heterogeneous content in two-phase fluid The manufacturer often claims that the volume percentage of free gas has little effect on measurement. When measuring liquids with small, well-distributed gas bubbles, such as ice cream and similar emulsions, the effect may be relative. Some models have no obvious effect when the air bubbles are 1%, some models have an error of 1%~2%, and one of the double-pipe straight pipes is as high as 10%~15%; when the air bubbles are 10%, the error generally increases to 15%~ 20%, individual models up to 80%. In addition, differences in fluid pressure, flow rate, viscosity, and gas-liquid mixing methods have different effects. When measuring liquids containing a small amount of solids, all types of CMF have high reliability. When the solid content is large or the solid has strong abrasiveness or soft solid (such as vegetable pieces in food soup), the single-tube straight-tube type or the series-connected double-tube type should be selected. Because if the parallel double-pipe type is used, foreign matter or wear may adhere to the shunt, which may change the flow of the two shunts and cause errors; more serious cases such as blockage of one way may not be found immediately. 5. Impact of environmental vibration CMF can work in a vibrating environment, but it must be isolated from vibration, such as connecting with the vibrating tube with a flexible tube and using a vibration-isolated support frame. But it should be prevented that the vibration frequency is the same as the working frequency or harmonic frequency of CMF. Multiple instruments of the same model are installed in series or relatively close to each other, especially on the same support platform. The vibrations of the operating frequencies of each CMF will affect each other, causing abnormal vibration, and in severe cases, the instrument will not work. When ordering, it can be specially proposed to the manufacturer to stagger the working frequency of the two series CMFs. 6. Influence of pipeline stress If the center of the pipeline connected to the flow sensor is misaligned (or not parallel) or the temperature of the pipeline changes, the pipeline stress will form a pressure, tension, or shear force to act on the alignment between the CMF measuring tubes, causing the detection probe to fail. Asymmetry, resulting in zero-point shifts. The CMF must be zeroed after installation to eliminate or reduce this effect. If the tubing is severely misaligned, zeroing may not be possible. If the temperature of the pipeline deviates from the temperature at the time of installation, the thermal expansion (or contraction) force generated by the pipeline will also act on the flow sensor. Some CMF designs have a heavy flow divider at the inlet and outlet of the measuring tube, which can reduce the influence of pipe stress on the measuring tube. The straight measuring tube CMF is particularly susceptible to the influence of thermal expansion force, and thermal expansion isolation fittings can be installed in the pipeline if necessary.
There are many issues that affect vortex flow meter manufacturer, which has led to the need of getting specialists trained in certain areas so as to handle all issues that may arise as well as mass flow meter products that can solve v shape coriolis mass flow meter problems.
For more information on fork density meter manufacturer mass flow meter and how to find the best quality at the right price, check out Sincerity Mass Flow Meter Manufacturers.
Beijing Sincerity Automatic Equipment Co., Ltd provides a way for you to understand your customers, to learn what makes them unique and what motivates their behavior. We can then leverage that wealth of information to personalize our interactions and demonstrate that mass flow meter is valuable to our customers.
Beijing Sincerity Automatic Equipment Co., Ltd offers not only the high-quality product but also the finest service, gives the customer with an expressive using experience.
Now that Beijing Sincerity Automatic Equipment Co., Ltd has become a leader in the space and have been able to scale appropriately, we are ready to expand to other cities.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com