Abstract: the cause of the high temperature liquid meter scale measurement accuracy decline information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. In the process of using high temperature liquid flowmeter will find sometimes precision will decline, in the summary of the reasons are as follows: 1, the change of fluid temperature, pressure, liquid may make the pipe or escape of the air because of the pipe pressure is lower than the flow of saturated steam. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the cause of the high temperature liquid meter scale measurement accuracy down the article details. In the process of using high temperature liquid flowmeter will find sometimes precision will decline, in the summary of the reasons are as follows: 1, the change of fluid temperature, pressure, may make the escape of the liquid in the pipe air or because of the pressure inside the pipeline is lower than fluid saturation vapor pressure, make part of the liquid and steam, may also be because of the medium pressure make the outside air is sucked into the pipe, the gas with the measured liquid, causing instrument indicated value increase, there is error, adverse to the fluid of the buyer. 2, poor working environment will be a larger impact on the result of the high temperature liquid flowmeter measurement, such as electromagnetic interference, dust, high temperature, vibration, humidity, etc. , may cause a malfunction or failure of turbine flow sensor, the direct cause of flowmeter, of error of error is positive or negative, may not be obvious, may complete failure. For the above phenomenon, the more serious when, can find problems from the comparison the working state of the process, easy to take corresponding measures. But, in the early part of the problem, don't take special measures can't found the problem. 3, usually have some impurities in medium, to produce the wear of bearing, axis, the gap between the two increases, moving parts of dynamic balance is destroyed, speed drops, or dirt into the gap, make motion resistance increases, speed down. All of these reasons resulting in a decrease of instrument display value, negative error, adverse to the fluid of the supplier. 4, fluid of fibrous or viscous impurities attached to the rotating part of the liquid flow meter, make rotational resistance increases, resulting in a decrease of instrument of the indicated value, the negative error, adverse to the fluid of the supplier. So, the instrument need preventive maintenance, to ensure flow meter in normal use for a long time. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd offers a ton of features and capabilities to help you acquire and retain customers, boost sales and manage contacts.
Beijing Sincerity Automatic Equipment Co., Ltd has been a leading server of for many years. Visit the website Sincerity Flow Meter for quality mass flow meter.
mass flow meter, is an alternative product for tuning fork liquid density meter to investors and consumers who are passionate about our products or services.
The team of engineers and developers at Beijing Sincerity Automatic Equipment Co., Ltd are the best in their own way and we promise to provide timely service to our esteemed clients.
Beijing Sincerity Automatic Equipment Co., Ltd provides the ideal conditions for business creation – access to cash, human capital and affordable office space, for instance – can help new ventures not only take off but also thrive.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com