Abstract: the flow meter scale in shenzhen water group, the application of the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Shenzhen water group currently has to plant 5, raw water pumping station 3, the total capacity of water supply for 167. 50000 cubic meters/day. Four sewage factory, sewage treatment capacity of 102. 50000 cubic meters/day. Mainly for electromagnetic flowmeter with flowmeter, total of about 130, including DN40. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the application of meter scale in shenzhen water group article details. Shenzhen water group currently has to plant 5, raw water pumping station 3, the total capacity of water supply for 167. 50000 cubic meters/day. Four sewage factory, sewage treatment capacity of 102. 50000 cubic meters/day. Mainly for electromagnetic flowmeter with flowmeter, total about 130 units, more than one DN400 75, DN400 under 55 units. Zui large-diameter DN2400, used for raw water metering, zui small diameter measured for DN25 used for drug delivery. In addition, there is also a small amount of ultrasonic flowmeter and the turbine flowmeter. Because the electromagnetic flowmeter has high accuracy, good stability, undisturbed, etc, has always been my company first selection of flow meter, especially in waterworks, mostly with electromagnetic flowmeter. Electromagnetic flow meter in our applications can be roughly divided into three phases, mainly ABB - * phase KENT imported electromagnetic flowmeter, about a dozen units, basic it is in the east lake water, use at the beginning of eighty s, there are still few machines in use, the rest due to renovation off. These import flow meter is very good quality, and basically no maintenance, use more than a decade the precision and stability is very good. Because of this reason, in the later flowmeter selection in electromagnetic flowmeter has been got. The second stage is, represented by kaifeng instrument and meter plant B series electromagnetic flowmeter in the early ninety s, medium-term, basic it is with this kind of flow meter, instrument and meter plant imported ABB - this type of meter is kaifeng KENT technology production, with imported ABB - Compared to KENT electromagnetic flowmeter, technical performance are not much difference, but the price is much lower, so has been widely used. The third stage is the mid and late ninety s, with the Shanghai guanghua - Love and production joint venture with cologne, Germany M900 series of electromagnetic flowmeter and kaifeng instrument and meter plant introduction of ABB E - KENT zui new technology Mag electromagnetic flowmeter, become the third stage of the main application products. This kind of product in terms of quality, technology and function has large improvement, basic not seen problem in practical application. On the application of flow meter we are very pay attention to the following aspects: 1, pays great attention to the selection of flow meter, installation conditions and installation and debugging process. Flowmeter selection is very important, improper selection, will bring inconvenience for use in the future, can't even normal measurement. Bijia early landscape plant construction, for example, pump room water flowmeter selection of cologne, Germany with standard spool type ultrasonic flowmeter, the time difference between when the design without considering the characteristic of pump room water containing bubbles, cause meter mount has been not work properly after, necessity, and replaced with electromagnetic flowmeter. Again such as sewage plant sludge flowmeter metering, many chose electromagnetic flowmeter scraper blade, from the current application effect, due to the sludge contains a lot of solid particles, the sensor electrode and liner wear is very serious, scraper simply does not work, work flow meter is not very ideal, measurement error is too big. Therefore, used in the measurement of sewage flow meter generally flowmeter performance, you should also consider its abrasion resistance and the influence of the solid particles. Installation condition has a great influence on the flow meter used also, the flow meter manufacturers are also attaches great importance to and has clear requirements on site installation conditions, but in practice, because the site installation conditions can not meet the requirements of flow meter does not work always. Often the problems are: the valve or elbow flow meter too close, the requirements of the straight pipe is not enough, can't full tube flowmeter section water, etc. , all these things in my company, and spent a lot of money to undertake transforming.
Beijing Sincerity Automatic Equipment Co., Ltd is the largest manufacturer of mass flow meter, which is one of the best product manufactured from us.
Beijing Sincerity Automatic Equipment Co., Ltd is a mass flow meter services company that creates vortex flow meter manufacturer mass flow meter for v shape coriolis mass flow meter.Our services have brought great value to customers. Welcome to visit us at Sincerity Flow Meter.
If our brand is successful and consistent, it will be much easier to initially grab customers and encourage them to purchase mass flow meter further.
is something that has been around for a few decades now, enjoying it's heyday back in the rosemount vortex flow meter.
Sincerity is one of the top brands in their class when it comes to mass flow meter and low flow turbine flow meter. If you check online, Sincerity is often rated high and reviewed with much praise. we would be very pleased to receive your inquiry.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com