loading

Sincerity Group | Coriolis flow meter manufacturers| 

The advantages and disadvantages of electromagnetic flow meter scale concrete analysis

by:Sincerity Group     2021-10-03
Abstract: the advantages and disadvantages of electromagnetic flow meter scale concrete analysis information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. As the technology progress and production needs, metering technology got rapid development, especially a new generation of intelligent electromagnetic flowmeter, after decades of application and technology updates, use scope is extremely broad. By technology and shunda meter below small make up for. More flow meter manufacturers choose model price quote you are welcome to inquire, the following are the advantages and disadvantages of electromagnetic flow meter scale concrete analysis the article details. As the technology progress and production needs, metering technology got rapid development, especially a new generation of intelligent electromagnetic flowmeter, after decades of application and technology updates, use scope is extremely broad. By flowmeter technology below small make up for everybody to do electromagnetic flowmeter is a bit and the lack of specific analysis, for your reference. 1) Electromagnetic flowmeter sensor structure is simple, the measuring tube has no moving parts, no obstacles to fluid flow throttling components. So when the fluid flow through timing does not cause any additional pressure loss, flow meter is running in one of the flowmeters zui low energy consumption. 2) Measurable smudges medium, corrosive medium and clouding the liquid-solid two phase flow of traffic. This is due to internal unimpeded flow meter tube parts, and the measurement of body contact is sounding pipe lining and electrode, the materials can choose according to the nature of the current body. For example, made from poly three fluoride or ptfe lining, can measure all kinds of acid, alkali, salt and other corrosive medium. Adopt wear-resisting rubber lining, is especially suitable for measuring with solid particle slurry, water slurry, wear a large liquid-solid two phase flow and various liquid with fiber and pulp suspension. 3) Electromagnetic flowmeter is a kind of volume flow measuring instrument, in the process of measurement, it is not affected by the temperature of the measured medium, viscosity and density with conductivity ( In a certain range), The influence of. Therefore, electromagnetic flowmeter only after water calibration, it can used to measure the conductivity of liquid flow. 4) The output of the electromagnetic flowmeter is proportional to the average flow velocity of the measured medium only, and with the flow state of symmetrical distribution ( Laminar or turbulent) Has nothing to do. So the electromagnetic flowmeter range very wide range, the measurement range can be up to 100:1, some even up to 1000:1 working flow range. 5) Electromagnetic flowmeter without mechanical inertia, responsive, can measure the instantaneous pulse flow, also can measure the rate of flow of positive and negative two directions. 6) Industrial use very wide range of the calibre of the electromagnetic flowmeter, from a few millimeters to a few meters, and the domestic existing diameter up to 3 m's real flow calibration equipment, which laid a foundation for the application and development of electromagnetic flow meter. Electromagnetic flowmeter is still the main deficiencies are as follows. 1) Cannot be used to measure the gas, steam, and contains a lot of gas liquid. 2) Cannot be used to measure the low conductivity of liquid medium, such as the petroleum products or organic solvent such as medium, the electromagnetic flowmeter is powerless. 3) Ordinary electromagnetic flow meter used in industry due to the measuring tube lined with the limitation of materials and electrical insulation materials, can not be used in measuring high temperature medium; If without special treatment, also cannot be used for the measurement of low temperature medium, in order to prevent the measuring tube outer condensation ( Frost) Destruction of insulation. 4) The influence of electromagnetic interference electromagnetic flowmeter are susceptible to the outside world. Meter - Shaanxi flowmeter is suitable for the water/gas/gas/steam/air/oxygen/heavy oil/oil/ph/asphalt and other kinds of medium flow metering 【 Production capacity 】 Design production capacity of ten thousand sets every year' After-sales promise 】 24 months from the date of the product from the factory three guarantees, non-artificial damage to the quality problems, the company responsible for the repair, replacement or return, 3 bag period provide paid lifelong maintenance service. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Collectively, the effect of mass flow meter on industrial society has been to eliminate v shape coriolis mass flow meter and drastically reduce the time long associated with coriolis density meter.
What are you waiting for? Don't you want to provide perfect support to endress hauser coriolis mass flow meter? If yes, so, switch to mass flow meter right away!
Armed with professional team and advanced equipment, Beijing Sincerity Automatic Equipment Co., Ltd is specialized in offering high quality in various designs. Visit us at Sincerity Flow Meter to find your desired .
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: