Abstract: Talking about the requirements for the installation of sewage flow meters are provided by excellent flow meter and flow meter manufacturers. Electromagnetic flowmeter is a commonly used sewage flowmeter, which consists of transmitter and converter. After it is matched with the corresponding display and control instrument, it can be used to measure the liquid flow with conductivity and perform instruction, recording, accumulation and control. User is on. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is a brief description of the requirements for the installation of sewage flowmeters. Electromagnetic flowmeter is a commonly used sewage flowmeter, which consists of transmitter and converter. After it is matched with the corresponding display and control instrument, it can be used to measure the liquid flow with conductivity and perform instruction, recording, accumulation and control. What are the requirements for users to install sewage flowmeters? Let's introduce the installation requirements of sewage flowmeters in detail, hoping to help everyone. (1) Location selection The installation location must ensure that the pipeline is always filled with the liquid to be tested. Select the place where the liquid flow pulse is small, and keep away from the pump, valve, elbow and other local resistance parts. When measuring two-phase (solid, liquid and gas, liquid) liquids, a place that is not easy to cause phase separation should be selected. The inner diameter or circumference of the pipe under test is easy to measure, and the ovality should be small. (2) Environmental selection The equipment with strong electromagnetic fields, such as large motors, large transformers, large frequency converters, etc., should be kept away from the equipment as far as possible. There should be no strong vibration in the installation site, the pipeline is firmly fixed, and the ambient temperature changes little (to prevent the change of solid-liquid two-phase). The installation environment should be easy to install and maintain. (3) Length of straight pipe section The length of the straight pipe section on the upstream side of the sensor installation pipeline should be greater than or equal to 10D, and the downstream side should not be less than 5D (D is the diameter of the pipeline to be measured). (4) Flow control valve and regulating valve The flow control valve should be installed in the measured pipeline on the upstream side of the sensor, and the flow regulating valve should be installed on the downstream side of the sensor. When the flow rate, usually the flow control valve should be in the fully open state. Sewage flowmeter is a commonly used flow measuring instrument, mainly used for measuring the volume flow of liquids in municipal water supply, steel, petroleum, chemical, electric power, industry, water conservancy, water administration and water resources and other departments. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'What are the requirements for the installation of sewage flow meters'
Getting doesn't have to be expensive, time-consuming, or difficult. It all comes down to the right method and a u shape coriolis mass flow meter mass flow meter in place.
For more tips and strategies on effective coriolis mass flow meter emerson solutions, get your choice at Sincerity Flow Meter.
Beijing Sincerity Automatic Equipment Co., Ltd knew the only way to remain competitive was to ensure quality of service and customer satisfaction above all.
comes in a vast array of styles and endress hauser ultrasonic flow meter depending on which endress hauser coriolis mass flow meteris used.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com