loading

Sincerity Group | Coriolis flow meter manufacturers| 


Structure principle and installation guide of metal tube rotameter meter

Abstract: The structure principle and installation guide information of metal tube float flow meter are provided by excellent flow meter and flow meter manufacturers and quotation manufacturers. Structural principle of metal tube rotameter LZ series metal tube rotameter consists of two parts: sensor measuring tube and float; signal transmitter indicator; there are four kinds of liquid contact materials of sensor: stainless steel, Hastelloy, titanium, Stainless steel lined with PTFE; user. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the structure principle and installation guide article details of the metal tube float flowmeter. Structure principle of metal tube rotameter LZ series metal tube rotameter consists of two parts: Sensor———Measuring tubes and floats; signal transmitters———Indicator; There are four kinds of liquid contact materials for the sensor: stainless steel, Hastelloy, titanium, stainless steel lined with PTFE; users can meet the needs of process pressure resistance and medium corrosion protection according to different angular liquid materials. According to different measurement requirements, users can choose different indicator combinations when selecting models to achieve different measurement requirements. The flow measurement is accomplished by the transmitter in the indicator by coupling the magnetic steel to sense the change of the float position to complete the flow indication and the remote transmission of the signal. When the measured medium flows through the measuring tube from bottom to top, when the float is balanced by gravity, buoyancy and the vertical upward thrust of the fluid velocity on the float, the float is relatively stationary at a certain position, and this position varies with the float and the cone. The ring area of ​​the tube and the fluid flow rate change, and the position of the float corresponds to the flow rate of the measured medium. How to achieve accurate measurement of metal tube rotameter For the metal tube rotameter to work normally and achieve the required measurement accuracy, pay attention to the following points:·The flowmeter must be installed vertically, the fluid flows through the flowmeter from bottom to top, and the verticality is better than 2°, the horizontal angle is better than 2 when installed horizontally°;·The metal tube rotameter should be bypassed, which is convenient for troubleshooting and does not affect production during purging;·There should be a straight pipe section with a length of more than 5 times the pipe diameter at the inlet of the flowmeter, and a straight pipe section of 250mm at the outlet.·The medium contains ferromagnetic substances, and a magnetic filter should be installed;·If the medium contains solid impurities, it should be considered to install a filter between the valve and the straight pipe section;·When used for gas measurement, it should ensure that the pipeline pressure is not less than 5 times the pressure loss of the flowmeter, so that the float can work stably;·When the temperature of the measured medium is higher than 220°C or the temperature of the fluid is too low, crystallization is likely to occur, and when heat insulation protection measures are required, the jacket type should be used for cooling or heat preservation;·In order to avoid the deformation of the flowmeter due to the pipeline, the flange of the process pipeline must be coaxial with the flange of the flowmeter and parallel to each other, and the pipeline should be properly supported to avoid pipeline vibration and reduce the axial load of the flowmeter. The valve should be installed downstream of the flowmeter:·Since the metal tube rotameter transmits signals through magnetic coupling, in order to ensure the performance of the instrument, ferromagnetic substances are not allowed to exist at least 10cm around the installation; the above is the entire content of this article, you are welcome to inquire our factory for flowmeter selection type, price, etc. 'Metal tube float flow meter structure principle and installation guide'

Maintaining electromagnetic flow meter slurry is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.

To live healthy, you need to eat healthy; to eat healthy, you need to think healthy; to think healthy, you need to read health; to read healthy, you need to follow Sincerity Flow Meter.

To find a qualified at reasonable price, contact Beijing Sincerity Automatic Equipment Co., Ltd at Sincerity Flow Meter, a professional provider and tell them what you envision for your mass flow meter.

Beijing Sincerity Automatic Equipment Co., Ltd’s mission is to provide you with an outstanding member/Customer benefit that helps you meet your organization’s objectives.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect