To solve the problem before we must first understand what is split type electromagnetic flowmeter zero unstable phenomenon? Popular speak be electromagnetic flowmeter under normal working conditions, liquid crystal display (LCD) will have irregular beating 'figure 1' such as 2. If 8 t/H to 4. 86 t / H 5。 85 t/H that is zero unstable phenomenon, if the jump to 2. 7/2. 8 t/H this is qualified within the normal range. Problems always have a good solution, below small make up by checking the five steps to tackle the problem, split type electromagnetic flowmeter zero unstable phenomenon and check the five-step figure '1', electromagnetic flowmeter sensor imperfect ground by stray current interference, such as pipeline stray current interference effect mainly electromagnetic flowmeter good grounding protection, usually requires grounding resistance less than 1000, don't and he Shared grounding electric machines and appliances. Sometimes better environmental conditions, electromagnetic flowmeter earthing can not work normally, but once the good environment does not exist, the instrument will fail, then checked again will bring much trouble. Flow sensor near the state changes of electric power equipment ( Such as leakage current increase) Formed by the ground potential changes, electricity will cause electromagnetic flowmeter zero change. Second, the first rule out check: check zero electromagnetic flowmeter unstable process. Press process fully consider first makes a preliminary research and judgment, and then detailed item by item check and test troubleshooting. The process to inspect items listed in the order of successively principle is: ( 1) By observing or ask understand without large operations in the former, namely after the first difficult; ( 2) According to the on-site maintenance experience in the past, the higher the frequency is higher and the future possible probability in the former; ( 3) Check itself needed successively. If several failure after preliminary investigation team indeed sufficient reason, also a detailed inspection in advance. Split type electromagnetic flowmeter zero unstable phenomenon and check the five step three, check the insulation resistance of electrode and electrode contact resistance: (points 2 steps 1) Filled with liquid measuring scoop of electrode surface contact resistance flow sensor signal cable wiring, each electrode is measured with a multimeter, respectively, and the ground, resistance between two electrodes of geoelectric elder sister value should be left in the 10% to 20%. Section 9 & quot; A/electrode contact resistance measurement & quot; There will be further instructions. ( 2) Atc measuring electrode insulation vent pipe, wipe with dry cloth in the inner surface, after being completely dry, use H500VDC megohmmeter measure the resistance between the electrode and ground, resistance must be in the 100 m & Omega; The above. In general, through the above five steps of inspection and operation, basic can solve zero unstable situation. Four, electromagnetic flowmeter signal circuit insulation. Unstable signal circuit insulation fall will form the zero. Soil to reason for the declining signal circuit insulation of foot, package parts drop caused by the insulation, but also can't rule out signal cable and terminal decline or insulation damage. Because sometimes the environment is very harsh, slightly one careless negligence meter cover/wire joint sealing, filled with moisture acid mist or powder dust intrusion meter connector or cable protection layer, decreased insulation. Signal circuit insulation resistance check respectively according to the cable side and the flow sensor side two mail points, with a megger test. Because of signal cable can do easily. Flow sensor is divided into two: strider liquid-filled test electrode surface and a tube after measuring contact resistance, U insulation resistance. Five, the electromagnetic flowmeter liquid ( Such as liquid conductivity uniformity, electrode pollution, etc. ) The reason; In static liquid conductivity changes or uneven make zero changes, shook the output flow. So flowmeter position should be far away from the injection solution point or pipe section downstream of the chemical reaction, good flow sensor * in upstream of the sites. If the liquid to solid phase, or to measure impurities deposition tube inner surface, or on the inner wall of the measuring tube fouling, or electrode by grease filth and so on, all have zero changes may occur. Because the lining surface scale and degree of filth and electrode can't completely the same and symmetrical, destroy the balance of the initial die set. Positive measures to remove filth and scale deposit layer; If zero little change can also try to zero. Problems by accident, and inevitable, hope that through fission type electromagnetic flowmeter zero unstable phenomenon and check the five-step help you, such as still don't understand, not to contact us!
Whenever the question of mass flow meter tuning fork liquid density meter is raised, one comes across the term ''.
Check out offers at Sincerity Flow Meter and read exclusive reviews on latest rosemount vortex flow meter mass flow meter on our website.we are looking forward to creating mutual benefits with you.
When it comes to mass flow meter coriolis mass flow meter emerson, Beijing Sincerity Automatic Equipment Co., Ltd is the name to reckon with. Not only are they best, they are the most experienced as well and provide wide range of services as well as products at affordable prices. Find out more information on Sincerity Flow Meter.
More than half of customers said they have faith with Beijing Sincerity Automatic Equipment Co., Ltd and mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com