loading

Sincerity Group | Coriolis flow meter manufacturers| 


Smart Water Meter Installation Guide

Abstract: Smart water meter installation guide information is provided to you by excellent flowmeter and flowmeter production and quotation manufacturers. Smart Water Meter Installation Guide A water meter is a flow meter, a measuring instrument for correct measurement and rational distribution of water resources. Wang Dongwei, director of the flow room and associate researcher of the China Institute of Metrology, pointed out in an interview with reporters a few days ago that in order to ensure the water meter. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following are the details of the smart water meter installation guide article. Smart Water Meter Installation Guide A water meter is a flow meter, a measuring instrument for correct measurement and rational distribution of water resources. Wang Dongwei, director of the flow department and associate researcher of the China Institute of Metrology, pointed out in an interview with reporters recently that in order to ensure the accuracy of water meters, while implementing strong inspection and strengthening supervision and management of water meter products on the market, the installation and use of water meters should also be Pay attention to other aspects. Water meter installation specifications Three factors to be considered in water meter installation Correct installation of water meters is a necessary guarantee to ensure the accuracy of water meter measurement. Water meter national standard GB/T778.2—1996 is the standard on water meter installation requirements. The installation of water meters must consider safety, convenience and correct reliability. The installation of the flowmeter for measuring water can refer to its corresponding requirements. 1 Safety (1) Before installing the water meter on the newly laid pipeline, the sundries in the pipeline must be cleaned before installation, so as not to damage the water meter or affect the normal operation of the water meter after the water is passed through. (2) When the water meter is installed, it must be considered that the water pressure and water temperature used on site are within the maximum operating pressure and maximum operating temperature of the water meter. When installing a small-caliber civil water meter, you should also pay attention to whether the connecting pipe and pipe nut of the water meter feel particularly thin, so as to avoid installing fake and inferior water meters. (3) Water meters installed outdoors should generally be installed with a protection box, and should not be installed in exposed and frozen places to prevent external damage. In severe winter, water meters installed outdoors should have antifreeze measures. Note: Water supply companies in the north (north of the Yangtze River) stipulate that the location of water meters installed outdoors is generally below the permafrost layer. Indoor heating can ensure that the indoor water meters are not frozen and cracked, but the situation is better than that in the south. (4) Anti-theft should be considered, especially copper shell water meters. (5) The location where the water meter is installed should also avoid the erosion of corrosive gases. (6) If the industrial water meter is installed near the boiler, a check valve should be installed behind the meter to prevent the hot water from flowing back and damaging the water meter parts. 2 Convenience The installation location of the water meter should be as convenient as possible to read and read the meter, and the convenience of maintenance and meter replacement should also be considered. (1) For water meters installed outdoors, it is necessary to choose a location that is dry, sand-proof, groundwater-proof, and insect-proof. (2) When the water meter is installed underground, in order to facilitate the replacement of the water meter, two stop valves must be installed at both ends of the water meter. The water passage area of ​​the expansion device (telescopic tube, water filter tank, water filter net) installed at the front of the water inlet of the water meter should be 1 to 2 times the diameter of the water meter, so as to facilitate frequent inspection, replacement or cleaning. 3 Correctness The installation of the water meter must meet the requirements of its working mode, and it should meet the requirements of the water meter in terms of installation orientation, dial orientation and upstream and downstream straight pipe sections. (1) Most water meters have installation method requirements. H on the dial or nameplate stands for horizontal installation, V stands for vertical installation, without these two symbols, it can be installed in any direction. The dial of the water meter should be upward and not tilted. The flow direction of the water meter should be consistent with the flow direction of the water in the pipeline. Some water meters (such as volumetric water meters, etc.) can be installed in any direction. (2) The water meter should be installed so that the direction of the arrow on the case is consistent with the flow direction of the water in the pipe, and it should be installed coaxially with the pipe. (3) The dial of the water meter installed horizontally is generally upward and shall not be inclined. It is not possible to adjust the orientation of the indicator dial of the reading water meter just considering the convenience of reading. Description: Some dry water meter fishing reading indicators can be 360‘Rotate for easy reading. When the water meter is installed vertically or obliquely, the impeller shaft and the centerline of the pipe must be kept parallel. (4) The straight pipe sections upstream and downstream of the water meter must meet the requirements of the instruction manual, especially for speed-type water meters. Horizontal screw-foil water meters and single-beam water meters are particularly required for straight pipe sections. Downstream of the water meter, there should be a part higher than the water meter (such as a faucet) or maintain a certain pressure, so that the water meter can always operate under the condition of a pipeline full of water. (5) The position of any pipeline downstream of the water meter should be higher than the position of the water meter to ensure that the water meter works under the condition of full pipe flow. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. Smart Water Meter Installation Guide

Wow, this sounds like a bit of a cruel question, but it is a vitally important question to ask yourself if you are struggling with your low flow turbine flow meter and you would like to stop the mass flow meter problem.

Beijing Sincerity Automatic Equipment Co., Ltd supports these goals with a corporate philosophy of adhering to the highest ethical conduct in all its business dealings, treatment of its employees, and social and environmental policies.

Once we have a good idea of how mass flow meter can satisfy customer’s needs, consider whether we should create a skill for their demands.

Our company specializes in selling mass flow meter as well as providing relevant services.

Beijing Sincerity Automatic Equipment Co., Ltd employs a group of professional staff, enhancing the function of mass flow meter.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect