Six Requirements for Vortex Flow Meter Supplier Installation Location Selection

by:Sincerity Group     2022-06-05
Six Requirements for Vortex Flowmeter Supplier Installation Location The correct installation of the vortex flowmeter is directly related to the measurement accuracy of the flowmeter, so the correct installation of the vortex flowmeter is crucial. Thermal gas mass flow meters are instruments that measure gas flow using the principle of thermal diffusion. The sensor consists of two reference-grade RTDs. One is a speed sensor RH, and the other is a temperature sensor RMG that measures the change in gas temperature. Vortex flowmeter is a volume flowmeter that measures the volume flow of gas, steam or liquid, the volume flow of standard conditions or mass flow according to the principle of Karman vortex flow. Compressed air flowmeter can be measured by target flowmeter, which not only has the characteristics of traditional orifice plate, turbine, vortex and other flowmeters without moving parts, but also has the measurement accuracy comparable to that of positive displacement flowmeter. Let's get straight to the point. The flowmeter has some special instructions for the installation location. 1. The flow direction mark on each sensor is consistent with the flow direction of the measured medium in the boiler. 2. Installation requirements ensure that the conductive liquid is always filled with the measured medium. 3. Avoid very small amounts of non-corrosive gases in the environment. Floods can be avoided only when the relative ambient temperature is less than 10%—90%. 4. Choose the place where the fluid flows pulsatingly, that is, away from the pressure loss parts of the pump (valves, elbows, etc.). 5. When measuring two-phase fluids, choose a place where complete separation is difficult. 6. Minimize and avoid negative pressure in the measuring pipeline. Requirements for the middle pipe section: 1. The requirements for the various sensors in the upstream straight pipe section are 5 times the diameter of the various sensors. 2. When the channel diameter of the upstream or downstream straight pipe section is inconsistent with the channel diameter of the inductor, an expansion pipe or a tapered pipe with a taper angle less than 150 should be installed and then connected to it. 3. The flow signals generated by other sensors are very weak, usually microvolts and millivolts, so it is very important to prevent external pulse interference. These are the requirements to be aware of when choosing a vortex flowmeter location.
One increasingly popular managerial tactic to improve problem-solving performance of mass flow meter is to increase the connectedness, or what academics call clustering, of the organization
Beijing Sincerity Automatic Equipment Co., Ltd provides which will help you tuning fork liquid density meter in a durable and reliable way. To learn more, go to Sincerity Flow Meter.
When selecting the best products for customers, we considered not only the mass flow meter, but also the electromagnetic flow meter slurry.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: