Several meter scale installation specification technical requirements

by:Sincerity Group     2021-07-27
Abstract: several meter scale installation specification technical requirement information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Plug-in vortex street flowmeter installation technical requirements: 1, former straight pipe length is not less than 10 d; 2, after the straight pipe length is not less than 5 d; 3, in line with gas welding open a slightly smaller than ф 100 mm round hole, and put the round hole deburring around clean, to ensure the measuring head. More flow meter manufacturers choose model price quote you are welcome to inquire, here are some technical requirements for the article details meter scale installation standard. Plug-in vortex street flowmeter installation technical requirements: 1, former straight pipe length is not less than 10 d; 2, after the straight pipe length is not less than 5 d; 3, in line with gas welding open a slightly smaller than ф 100 mm round hole, and put the round hole deburring around clean, to ensure the measuring head rotating fluent; (4), round holes in pipe welding manufacturers provide flange, requirements flange axis perpendicular to the pipe axis; 5, the ball valve and the sensor installed on the welded flange; 6, regulating screw, insert depth accords with a requirement, the direction of flow must be consistent with the direction arrow label instructions. 7, uniform tighten the screws on the gland; 8, the electrical outlet cables should be bent into a U shape, avoid water along the cable into the amplifier shell; Around 9, instrument installation points should leave some space, in order to install the wiring and regular maintenance; Full tube type vortex street flowmeter installation technology requirements: 1, 10 d straight pipe length before; 2, straight pipe length after 5 d; 3, in pipeline welding manufacturers provide flange, requirements flange axis perpendicular to the pipe axis; 4, sensor installed on the welded flange; 5, the direction of flow must be consistent with the direction arrow label instructions. Electromagnetic flowmeter installation technical requirements: 1, the straight pipe not less than 30 d (before When mixed liquid) ; 2, straight after the period of not less than 5 d; 3, give priority to choose vertical pipe; To use torque wrench fastening nut, diameter (zui big moment for 55 n, m, diameter of DN40 zui large torque 43 n, m; 5, easy to installation, maintenance, maintenance, around the flow meter to have ample installation space; ) Throttling orifice meter installation technology requirements: 1, former straight pipe not less than 8 d; 2, straight after the period of not less than 5 d; 3, gripping the throttling parts with flange and pipe welding, flange seal face should be perpendicular to the pipe axis, and the flange axis coincidence to the pipe axis, flange sealing surface nozzle welds are not allowed to have raised welding meat, should burnish is flat and level. Using butt welding flange, flange diameter must be equals the process pipe diameter, and process piping flange axis centre axis, nozzle alignment, does not allow any welding residue inside weld; 4, throttling device and pressure pipe material is stainless steel, must adopt argon arc welding. 5, gaskets and pipe coaxial, does not allow bias; 6, the throttle device take pressure bearing and the center line of the process piping level; 7, the installation direction of annulus, annulus with & other; +” On one side of the logo should be installed on the upper side of the throttle device; 8, throttling device before installation should be carefully cleaned and throttling element bruised, clear the antirust oil clean; 9, throttling device in pipe is clean before installation; 10, the installation of condensing tank should be in the same height, the same level; 11, instrument display section should facilitate the observer direction; Target type flow switch installation technical requirements: 1, the medium flow direction with the direction arrow on the shell; 2, target and medium flow direction vertical controller; 3, before the controller should be 10 diameters of oriented straight; Golden lake luen Thai instrument: ms song: the above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
The point for Beijing Sincerity Automatic Equipment Co., Ltd is that managerial processes are as important as other inputs in production and can create significant competitive advantage.
For more information please see our site at Sincerity Flow Meter. Don't be hesitate to contact us!
What Beijing Sincerity Automatic Equipment Co., Ltd discovered was that innovation occurs when business models match up with one or more of the mass flow meter where technological advances overlap with market needs, thus resulting in growth and transformation.
Loyalty programs provide an opportunity to learn the preferences of customers and design communication strategies that will resonate with mass flow meter.