Abstract: the selection of gas meter scale factor to consider information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Customers for site selection flow model selection of the timing is very important step, the actual working condition of the site should be considered to select the zui suitable measurement instrument, and the following shunda flowmeter and share about gas flowmeter selection factors to consider:. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a selection of gas meter scale factor to consider the article details. Customers for site selection flow model selection of the timing is very important step, the actual working condition of the site should be considered to select the zui appropriate measuring instrument, the following by the flow meter and share about gas flowmeter selection factors to consider: 1, the level of accuracy: in general, selects the turbine flowmeter is mainly focuses on its high accuracy, but the higher the accuracy of flowmeter, more sensitive to the change of site conditions of use, therefore, the selection of precision instrument carefully, should from the economic point of view. Trade settlement instrument, for large diameter gas pipeline on the instrument investment is more economical, and on the occasion of medium accuracy with low throughput level. 2, flow range: the choice of turbine flowmeter flow range have large effects on the accuracy and use fixed number of year, and each diameter of flowmeter has the certain measuring range, flow meter caliber choice is determined by the flow range. Select the principle of the flow range is: zui small flow rate shall not be lower than when using the instrument allows measuring zui small flow rate, when using the zui big flow rate shall not be higher than the instrument allows the measurement of zui traffic. For instrument operation time is not more than eight hours a day in the intermittent work situation, choose the actual when using zui large flow rate of 1. Three times as the maximum flow range; For daily instrument the actual running time no less than eight hours of continuous work situation, choose the actual when using zui large flow rate of 1. Four times as flow range limit. Instrument minimum flow used in actual zui small flow of 0. Eight times as appropriate. 3, the density of the gas, the gas meter, the influence of fluid physical properties mainly gas density, its effect on the meter coefficient is larger, and mainly in the low flow area. If gas density change frequently, to meter the flow coefficient of correction measures. 4, the pressure loss: as far as possible choose small pressure loss of turbine flowmeter. Because the smaller the pressure loss of fluid through the turbine flowmeter, the fluid from input to output pipe the energy they consume less, that the total power will be reduced, thus can greatly save energy, reduce the transportation cost, improve the utilization rate. Someone did test, pressure loss of the influence of main component is a former director of turbine flowmeter, choose diverter before half ellipsoid compared with before choosing pyramidal flow diverter, the pressure loss of the turbine flowmeter can be greatly reduced. 5, structural type: ( 1) Internal structure appropriate chooses the type turbine flowmeter. Because the push structure within a certain range of traffic in a floating state, can make the impeller axial there is no contact point, endless surface friction and wear, can prolong the service life of bearing. ( 2) According to the pipeline connection mode selection, flowmeter has two ways of the horizontal and vertical installation, horizontal and pipeline connection flange connection, threaded connection and connection. Medium caliber choose flange connection; Small diameter and high pressure pipeline choose threaded connection; Clamp connection is only applicable to low pressure pipe diameter; Vertical installation only threaded connections. ( 3) According to the environmental condition selection, considering the influence of temperature and humidity. Natural gas measurement to choose this type explosion-proof turbine flowmeter. 6, bearing, bearing of turbine flowmeter will typically have three classes of tungsten carbide, ptfe, carbon graphite material. Natural gas metering instrument bearing should choose tungsten carbide material. If you have other questions about flowmeter welcome consultation. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Sincerity is the unique producer of mass flow meter and related products.
Boasting good reputation in the industry, Beijing Sincerity Automatic Equipment Co., Ltd is the leading mass flow meter supplier, offering high quality and mass flow meter services for homes and enterprised all over the world. More info on Sincerity Flow Meter.
There are different types of , mainly tuning fork liquid density meter and low flow turbine flow meter.
Being focused on the goals of mass flow meter, our team, and most importantly, ourselves is critical to long-term success.
Digging into our roots and acknowledging out heritage can be fruitful on both a high-quality and professional level of mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com