Abstract: The information on the requirements of the steam flow meter for the straight pipe sections before and after the pipeline is provided by the excellent flow meter and flow meter manufacturers and quotation manufacturers. (1) Installation requirements of the instrument pipeline: The vortex flow meter has certain requirements for the upstream and downstream straight pipe sections of the installation point, otherwise it will affect the flow field of the medium in the pipeline and affect the measurement accuracy of the instrument. The length requirements of the upstream and downstream straight pipe sections of the instrument are shown in Figure (3). For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the requirements of the steam flowmeter for the straight pipe sections before and after the pipeline. (1) Installation requirements of the instrument pipeline: The vortex flow meter has certain requirements for the upstream and downstream straight pipe sections of the installation point, otherwise it will affect the flow field of the medium in the pipeline and affect the measurement accuracy of the instrument. The length requirements of the upstream and downstream straight pipe sections of the instrument are shown in Figure (3) DN is the nominal diameter of the instrument. Unit: mm Note: The regulating valve should not be installed upstream of the vortex flow instrument as much as possible, but should be installed 10D downstream of the vortex flow instrument. 1. The inner diameter of upstream and downstream piping should be the same. If there is a difference, the inner diameter Dp of the piping and the inner diameter Db of the vortex meter meter should satisfy the following relationship: 0.98Db≤Dp≤1.05Db The upstream and downstream piping should be concentric with the inner diameter of the flow meter, and the misalignment between them should be less than 0.05Db2. The gasket between the instrument and the flange should not protrude into the pipe during installation, and its inner diameter should be 1-2mm3 larger than the inner diameter of the meter. Installation design of pressure measuring holes and temperature measuring holes. When the pipeline under test needs to be installed with temperature and pressure transmitters, the pressure measuring hole should be set at 3-5D downstream, and the temperature measuring hole should be set at 6-8D downstream, see Figure (7). D is the nominal diameter of the meter, unit: mm The above is the entire content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Requirements for Steam Flow Meters for Straight Pipe Sections Before and After the Pipeline'
Beijing Sincerity Automatic Equipment Co., Ltd's has been able to achieve excellent performance in an extremely competitive industry.
Always do our research, follow the rules and plans ahead for additional expenses. Expanding is the goal of Beijing Sincerity Automatic Equipment Co., Ltd; expanding properly is the goal of the wise business.
According to the market analysts, exports from Beijing Sincerity Automatic Equipment Co., Ltd facilities in China will exceed the forecast.
mass flow meter continued to evolve to having strong manufacturers develop huge marketers and people came to value their opinions about what to buy.
Beijing Sincerity Automatic Equipment Co., Ltd have been an established and popular company with an excellent track record for the best customer satisfaction.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com