Abstract: The information on the precautions when installing the intelligent vortex flowmeter is provided by the excellent flowmeter and flowmeter manufacturers. 【Introduction】Vortex flowmeter is widely used in various industries to measure gas or liquid flow. It has its own advantages that many rotameters do not have. The process of installing a vortex flowmeter is very important. Correctly install the vortex flowmeter. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details of the precautions when installing smart vortex flowmeters. 【Introduction】Vortex flowmeter is widely used in various industries to measure gas or liquid flow. It has its own advantages that many rotameters do not have. The process of installing a vortex flowmeter is very important. The correct installation of vortex flowmeter can play a multiplier effect. Vortex flowmeter has unparalleled measurement flexibility, high reliability, excellent measurement performance, durability and low cost in actual measurement applications. The vortex flowmeter can be installed directly on the pipeline, and the meter can work well at any angle from vertical to horizontal. The signal converter can also be integrated with the flowmeter body as 270°rotation angle. vertical pipe installation with“batch”The working method is better, to ensure that the liquid is filled with the pipeline (the flow direction must be from bottom to top). If the vortex flowmeter is installed improperly, it will cause the vortex flowmeter to not work properly, or the displayed measured value to be inaccurate. Let's talk about how to install the vortex flowmeter correctly. The installation precautions of the vortex flowmeter are as follows: 1. The flange size of the connecting pipeline must be the same as the nominal size of the instrument, and the flange hole should be smooth, preferably a butt welding flange; 2. The flowmeter must be installed in a place without obstacles. On the straight pipe; 3. Be careful not to cause the fluid to generate steam when installing the flange sealing ring; 4. The flowmeter cannot be installed at the inlet and outlet of the pump, and the pump often produces oscillating fluid, which will affect the vortex flowmeter. Vibration; 5. If the flowmeter is installed at the outlet of the pump, it will experience severe flow pulsation, causing damage to the sensor; 6. The flowmeter installed near the vibration control valve will cause the same damage; 7. Four times the pipeline upstream of the meter The inner surface of the pipeline within the diameter and the range of twice the diameter of the downstream pipeline should be free of swarf, sand holes, cracks, protrusions and other surface irregularities; 8. When installing the instrument, the maintenance convenience of the instrument should be considered. If the fluid cannot be interrupted when the sensor is replaced, an isolation branch pipe should be installed before installing the flowmeter; 9. It is best to install a bypass pipe so that the entire instrument can be removed during maintenance. 10. When measuring liquid, it is recommended to install the flowmeter upstream of the regulating valve, so as to ensure full pipe and sufficient back pressure to avoid liquid flashing and cavitation; 11. When measuring gas, there are several installation methods. For the largest measurable range, it is recommended to install the flowmeter 10 to 30 times the pipe diameter or farther downstream of the regulating valve, which can ensure that the flowmeter has the maximum flow rate, so that the sensor can generate the most effective signal; 12. If the fluid flow is stable, the flowmeter can be installed upstream of the regulating valve, because the pressure fluctuation upstream of the regulating valve is usually small; 13. When measuring steam, it is recommended to install the flowmeter in the pipeline 10 to 30 downstream of the regulating valve. Diameter distance, this is particularly effective for measuring saturated steam, to ensure minimal condensation at the flowmeter. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Precautions when installing a smart vortex flowmeter'
Owing to its v shape coriolis mass flow meter and coriolis mass flow meter emerson benefits, has become a buzzword in the endress hauser ultrasonic flow meter market.
Now you can buy cheap at wholesale price at Beijing Sincerity Automatic Equipment Co., Ltd! Do visit Sincerity Flow Meter for great deals!
Offering a loyalty program not only makes customers feel valued, but it allows Beijing Sincerity Automatic Equipment Co., Ltd to easily collect important information about customers.
Beijing Sincerity Automatic Equipment Co., Ltd will need to find one that fits our needs and budgets, and still turns out a quality product.
The more people who do a certain thing, the more likely others are to do it as well. When Sincerity can demonstrate their popularity or satisfaction across a wide customer base, other consumers are more likely to buy in as well.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com