loading

Sincerity Group | Coriolis flow meter manufacturers| 

Precautions for integrated orifice flow meter

by:Sincerity Group     2023-03-26
Abstract: The information on the precautions of the integrated orifice flow meter is provided by the excellent flow meter and flow meter manufacturers. The integrated orifice plate flowmeter consists of three parts: sensing, transmission and operation display. It is mainly suitable for industrial measurement of saturated steam, superheated steam, compressed air, mixed non-flammable and explosive gases and hot water. Flow measurement, display, metering. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the article on the precautions for integrated orifice flowmeters. The integrated orifice plate flowmeter consists of three parts: sensing, transmission and operation display. It is mainly suitable for industrial measurement of saturated steam, superheated steam, compressed air, mixed non-flammable and explosive gases and hot water. It can be used for flow measurement, display, metering and online automatic control of production process. 1. The pressure guiding pipe must be filled with water or the injected high-temperature steam must be cooled before starting the operation. The straight pipe section before and after the throttling part of the integrated orifice plate flowmeter must be straight, and the straight pipe section for installing the throttling part should be smooth. If it is not smooth, the flow coefficient should be multiplied by the roughness to correct the sparseness. 2. A long enough straight pipe section is required before and after the throttling piece, and the upstream side of the throttling piece is an open space or diameter≥2 large containers, the length of the straight pipe between the open space or the large container and the throttle shall not be less than 30 (15). If there are other local resistance parts between the throttling part and the open space or the large container, in addition to the specified minimum straight pipe length 1 between the throttling part and the local resistance part, from the open space to the throttling part The total length of straight pipe sections between flow parts shall also not be less than 30 (15). How to use the integrated orifice flowmeter correctly: 1. The pressure guiding pipe system is filled with cold water as the pressure guiding medium, and the measurement of high temperature steam is generally conducted through cold water. When the pipeline is not transporting steam, open the primary valve, pressure valve and balance valve, close the drain valve, and directly inject cold water from the water injection hole of the condensate tank until it is fully filled. Of course, the balance valve and pressure valve can also be closed, and the valve can be opened once to introduce high-temperature steam and slowly cool it into water. This method is generally not used because the steam temperature is too high and it is easy to damage the instrument. Special attention should be paid to the measurement of high temperature steam when the pressure guiding pipe is not filled with water or the temperature is very high and it is strictly prohibited to put it into operation. Precautions for the use of the integrated orifice flowmeter: 1. The compressed air and cold water are measured directly by the medium. 2. After the differential pressure transmitter is exhausted or drained, after the pressure guiding pipe is filled with water, sometimes a small amount of gas will accumulate in the pressure chamber of the differential pressure transmitter to affect the pressure guiding, which must be eliminated. 3. Unscrew the bolts at the lower part of the positive and negative pressure chambers to drain the fluid. Generally, instruments newly put into operation do not need to be drained. Check that there is no leakage in the pressure guiding pipeline system, close all valves, and prepare to put into operation. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Precautions for Integrated Orifice Flow Meter'
Competitiveness policy of Beijing Sincerity Automatic Equipment Co., Ltd is about existing clusters as a platform for upgrading microeconomic fundamentals, where structural policies aim to change the industrial composition of an economy more directly.
We are an experienced supplier of and have gained good reputaion among global customers. With a wide range of in offer, we can customize according to your requirement. Send us your enquiry at Sincerity Flow Meter.
Beijing Sincerity Automatic Equipment Co., Ltd provides the ideal conditions for business creation – access to cash, human capital and affordable office space, for instance – can help new ventures not only take off but also thrive.
We have abundant experience in providing enhancement services and we are expert in mass flow meter.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: