Abstract: the plug-in electromagnetic flowmeter scale installation requirements information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Plug-in installation requirements and matters needing attention of electromagnetic flowmeter accurately measuring the quality of the need to choose the right instrument, instrument is the main, the second is to consider installation requirements, if the installation is not standard also cannot give full play to the role of the instrument, so for the flow. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a plug-in electromagnetic flowmeter scale installation requirements article details. Plug-in installation requirements and matters needing attention of electromagnetic flowmeter accurately measuring the quality of the need to choose the right instrument, instrument is the main, the second is to consider installation requirements, if the installation is not standard also cannot give full play to the role of the instrument, so for the installation of the flowmeter, we must consider, following Shanghai YiBi introduce you to the company's technical staff plug-in electromagnetic flowmeter installation requirements and precautions: 1, the plug-in electromagnetic flowmeter should as far as possible away from strong electromagnetic field devices; 2, the installation place should not have a strong vibration, pipe fixation, environment temperature changed; 3, installation location is always full of current body must ensure that the pipeline, sensors installed pipe straight pipe upstream side length is more than 8 d, downstream straight pipe length is not less than 5 d. 4, clean up the measured pipe installation pedestal welding slag and burr; 5, install DN80 ball valve installed to the base, pay attention to the the sky cavity up ball valve, check valve switch is normal; Install compression screw seat suite on the ball valve, loosen the screw and gland nut, insert the sensor rod through the ball valve inserted into the pipe to be tested. Sensor inserted depth of drawing out of the base 3 mm, meets the requirements, to tighten the screw and nut. At the same time pay attention to the sensor direction marks are consistent with the direction of flow. 6, the pipeline to be tested on the pipe hole is greater than the base, the base tube inserted into the pipe to be tested on open hole depth of crater flat on both sides; 7, the plug-in electromagnetic flowmeter is made of stainless steel electrode welding, after welding guarantee flange surface parallel to the pipe axis; 8, according to the specifications of plug-in electromagnetic flowmeter with converter scale device connected power supply and other wires, electricity inspection instrument display, after confirm the measured tube filled with fluid flow is zero, and check the meter should be zero; 9, the fluid flow in pipe to be tested and stable, check the instrument, according to the direction of the rotation sensor make the display value maximum, locking screw and gland nut; 10, for flow range is big, the fluid velocity is lower than the minimum flow velocity meter requires long-term occasions, consideration should be given to reduce the process piping or use two parallel installation of a large and a small flow meter; 11, plug-in electromagnetic flowmeter with normal electromagnetic flowmeter should be installed on the vertical process piping, which can prevent the suspended solid sinks down on the electrodes, at the same time make the fluid in the oil rises to the electrode measurement range, if the meter on the level of process piping installation, should make the sensor electrode in a horizontal axis, avoid the interference generated in the bubble, electrode lead to measure error; 12, vertical installation, the sensor should be inserted into the pipe and the vertical diameter of the pipe section Angle is less than 5 & deg; Small, suitable for measuring the pipeline vibration of cleaning medium; 13, tilt installation, the sensor axis and the axis of the pipeline to be tested for 45 Angle & deg; , and is suitable for big diameter and medium contain other impurities in the liquid flow measurement, small resistance of the installation of water, should not be bound to hang. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd offers a ton of features and capabilities to help you acquire and retain customers, boost sales and manage contacts.
Do you want endress hauser coriolis mass flow meter mass flow meter? We also have coriolis density meter. visit Sincerity Flow Meter to know more.
Beijing Sincerity Automatic Equipment Co., Ltd, which contributes itself on mass flow meter for creating more useful application.
Sincerity provides a number of u shape coriolis mass flow meter designed to handle fork density meter manufacturer.
Long gone are those days when coriolis mass flow meter emerson were used to endress hauser ultrasonic flow meter. Now new like rosemount vortex flow meter mass flow meter have come up.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com