On-site piping installation requirements for vortex flowmeters

Abstract: The information on the installation requirements of the vortex flowmeter on-site is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. 1. The pipeline where the vortex flowmeter is installed should be filled with the measured medium, and the flow direction mark of the vortex flowmeter should be consistent with the flow direction of the fluid in the pipeline. 2. It should be avoided to install on the pipeline with strong mechanical vibration. 3. When the measured medium contains a lot of impurities, it should flow in the vortex. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the article on the field pipeline installation requirements of the vortex flowmeter meter. 1. The pipeline where the vortex flowmeter is installed should be filled with the measured medium, and the flow direction mark of the vortex flowmeter should be consistent with the flow direction of the fluid in the pipeline. 2. It should be avoided to install on the pipeline with strong mechanical vibration. 3. When the measured medium contains a lot of impurities, a filter should be installed beyond the required length of the upstream straight pipe section of the vortex flowmeter. 4. The vortex flowmeter should be avoided to be installed in places with strong electromagnetic field interference, small space and inconvenient maintenance. 5. Requirements for the straight pipe section of the vortex flowmeter a. The flowmeter should be installed on a horizontal, vertical, inclined (liquid flow from bottom to top) pipeline with the same diameter. The upstream and downstream of the sensor should be equipped with straight pipe sections of a certain length, and the length should meet the requirements of 15~20D for the front straight pipe section and 5~1OD for the rear straight pipe section. b. If there is a reducer pipe upstream of the installation point of the flowmeter, the upstream of the flowmeter should have an equal-diameter straight pipe section of not less than 15D (D is the diameter of the pipe), and the downstream should have an equal-diameter straight pipe section of no less than 5D. c. If there is a gradually expanding pipe upstream of the installation point of the flowmeter, the upstream of the flowmeter should have an equal-diameter straight pipe section of not less than 25D (D is the diameter of the pipe), and the downstream should have an equal-diameter straight pipe section of not less than 5D. d. If the flowmeter is installed Point upstream has 90°For elbows or downlink joints, the upstream of the flow meter should have an equal diameter straight pipe section of not less than 20D, and the downstream should have an equal diameter straight pipe section of not less than 5D. e. If there are two 90s on the same plane upstream of the installation point of the flowmeter°Elbow, the upstream of the flow meter should have an equal diameter straight pipe section not less than 25D, and the downstream should have an equal diameter straight pipe section not less than 5D. f. If there are two 90s on different planes upstream of the installation point of the flowmeter°Elbow, the upstream of the flow meter should have an equal diameter straight pipe section not less than 40D, and the downstream should have an equal diameter straight pipe section not less than 5D. g. The flow regulating valve or pressure regulating valve should be installed as far as 5D downstream of the flowmeter. If it must be installed upstream of the flowmeter, when the valve can meet the full opening requirements, there should be a straight pipe section of equal diameter not less than 25D upstream of the flowmeter. , the downstream should have an equal diameter straight pipe section of not less than 5D. When the valve can only meet the half-opening requirements, the upstream of the flowmeter should have an equal diameter straight pipe section of no less than 50D, and the downstream should have an equal diameter straight pipe section of no less than 5D. h. If there is a piston or plunger pump, piston or Roots fan, compressor upstream of the flowmeter, there should be an equal diameter straight pipe section of not less than 50D upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D downstream. Special attention: If a valve is installed near the upstream of the installation point of the vortex flowmeter, and the valve is opened and closed continuously, it will greatly affect the service life of the flowmeter, and it is very easy to cause permanent damage to the flowmeter. Try to avoid installing the flowmeter on a very long overhead pipeline. After a long time, the sagging of the flowmeter will easily cause the leakage of the seal of the flowmeter on the flange. If it is installed, it must be installed upstream and downstream of the flowmeter. Pipe fastening devices are installed at the respective locations. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Requirements for On-site Pipeline Installation of Vortex Flow Meters'

The use and installation of mass flow meter is compared with most other systems for managing the coriolis density meter effectively and no doubt mass flow meter have won the race so many times.

For more tips and strategies on effective electromagnetic flow meter slurry solutions, get your choice at Sincerity Flow Meter.

There are ample scientific evidence of reducing the risk of rosemount coriolis mass flow meter.

Beijing Sincerity Automatic Equipment Co., Ltd quickly recognized the power of efficient manufacturing and started proactively recruiting people to sell products.

Natural has the distinct endress hauser coriolis mass flow meter which is irreplaceable.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.