Abstract: metal tube rotameter scale installation note information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. In order to guarantee the normal work of the metal rotameter and meet the requirements of measurement accuracy, the general should pay attention to the following: 1, metal rotameter must be installed vertically, fluid flows through the flowmeter from bottom to top, and vertical degree is better than that of 2, horizontal when the horizontal Angle. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a metal tube rotameter scale installation considerations article details. In order to guarantee the normal work of the metal rotameter and meet the requirements of measurement accuracy, the general should pay attention to the following: 1, metal rotameter must be installed vertically, fluid flows through the flowmeter from bottom to top, and vertical degree is better than 2 & deg; When mounted horizontally horizontal Angle is better than that of 2, & deg; ; 2, piped in process of metal tube float flowmeter should add bypass, in order to deal with failure or blow does not affect production; 3, if the medium containing ferromagnetic material, magnetic filters should be installed; 4, the entrance of metal rotameter is due more than 5 times the pipe diameter straight pipe, the length of the export shall be 250 mm straight pipe, to ensure the accuracy of measurement instrument; 5, when used for gas measurement, should guarantee the pipeline pressure is not less than five times the pressure losses of flow meter to float a stable work; 6, generally after the normal operation of the device, the product does not need maintenance, failure occurs when the device has just started, because the pipeline blow wash not clean, and float by solid particles sticking phenomenon, the indicator pointer is parked in a fixed position. First of all should be closed the valve on both sides of the flowmeter at this moment, and then remove the flange, remove float washed, packed again. Note on the fastening flange nut to balance tight, and take good washer if medium containing solid impurities, consideration should be given to the valve and straight pipe between the filter; 8, if the temperature of the measured medium is higher than 220 ℃ or prone to crystallization when the fluid temperature is too low, heat insulation protection measures should be taken to, should choose clamp cover model, for cooling or heat preservation; 9, flanges, fasteners, flange gasket and flowmeter standard to make the same instrument installed and run; 10, because the instrument is through magnetic coupling transmission signal, so in order to guarantee the performance of the instrument, install around at least 250 px, do not allow the existence of ferromagnetic material; 11, in order to avoid deformation caused by pipe flowmeter, process pipeline flange must be flange with meter coaxial and parallel to each other, properly pipe supports in order to avoid pipeline vibration and reduce the axial load meter, control valve should be installed downstream of the flow meter in measurement system; 12, the installation of PTFE lining instrument, be especially careful. Due to the uneven pressure, under the action of PTFE will deformation, so the flange nut evenly tighten symmetry; 13, measuring gas meter, is under pressure from a specific calibration, if the gas meter of export direct emissions to the atmosphere, will produce pressure drop on the float, and cause data distortion. If this is the working condition, a valve should be installed at the export of instrument; 14, instrument with lithium batteries, when installation should avoid direct sunlight, high temperature environment ( ≥ 65℃) So as not to reduce the capacity and life of lithium-ion batteries. 15 instrument with liquid crystal display (LCD), try to avoid direct sunlight when installation display, so as not to reduce the service life of the LCD above is all there is in this article, you are welcome to inquire me factory flowmeter selection, quotation, etc.
There is a strong need for more research on , in order to be able to provide strong and conclusive evidence of their v shape coriolis mass flow meter effects. However, recent studies have provided valuable insights into how the intake of may result in improved insertion ultrasonic flow meter.
Beijing Sincerity Automatic Equipment Co., Ltd is a reliable company that offers wonderful . In addition, the company also provides related components to make it more efficient. To know more, go to Sincerity Flow Meter.
To derive the optimal value out of endress hauser coriolis mass flow meter mass flow meter for your home, make sure they're purchased from a globally certified organization to ensure quality in use. Such an offer can be found at Sincerity Flow Meter.
Further dialogue of Sincerity between the approaches, the chapter concludes, could lead to actionable advice on more robust policies that drive both structural change and competitiveness upgrading.
Another way to maintain the professional yet engaging innovative technology in mass flow meter is by embedding new skills directly on manufacturing.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com