loading

Sincerity Group | Coriolis flow meter manufacturers| 


Measurement of steam flow meter scale and installation

Abstract: the measuring steam selects the meter scale and installation information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Rotor flowmeter, electromagnetic flowmeter, turbine flowmeter, etc are not to be used to measure the steam. Used to measure steam are using orifice meter. Now more and more people choose the vortex street flowmeter. , vortex flowmeter is characterized by low pressure drop. More flow meter manufacturers choose model price quote you are welcome to inquire, here is measuring the steam flow meter scale and installation details. Rotor flowmeter, electromagnetic flowmeter, turbine flowmeter, etc are not to be used to measure the steam. Used to measure steam are using orifice meter. Now more and more people choose the vortex street flowmeter. Vortex flowmeter is characterized by small pressure loss, wide range, high precision, working condition of the measurement volume flow is almost not affected by the fluid density, the influence of the parameters such as pressure, temperature, viscosity. No moving mechanical parts, so high reliability, small amount of maintenance. Instrument parameters can be long-term stability. Vortex street flowmeter using piezoelectric stress sensor, high reliability, can be in - Working temperature of 20 ℃ ~ + 250 ℃ within the scope of work. More than 250 degrees can make a capacitance type vortex flowmeter, a standard signal simulation, there is also a digital pulse signal output, easy, with digital systems, such as computers, is a kind of more advanced, the ideal measuring instrument. Vortex flowmeter with temperature compensation, temperature pressure one-piece vortex street flowmeter measurement when the steam is more stable and reliable. So what is the distinguishing feature of vortex street flowmeter measurement of steam: 1, pressure compensation table in the body at the same time integration temperature compensation function, measurable criteria or standard volume flow to mass flow of the fluid. 2, the intelligent and digital circuit design, can automatically compensate by flow volume density or standard of volume calculation. 3, a new digital filtering and correction function makes the flow measurement more accurate and reliable. 4, battery power without external power supply can work continuously for more than two years. 5, a new dot matrix Chinese character LCD display, operation more convenient. Vortex street flowmeter to measure steam flow timing installation which aspects need to pay attention to: ( 1) 。 Flow sensor can be installed in indoor or outdoor, avoid the high tension line, rotating machinery, poisonous and harmful environment, strong mechanical vibration environment, endanger the safety of person and instrument and used with flow sensor is not consistent with the conditions of temperature and humidity environment. Choice in the security, convenience of installation, debugging and maintenance, environment a better place. ( 2) 。 In the design of flow sensor installation location, besides considering conditions of straight pipe, also should give with sufficient space around the flow sensor, with convenient installation, debugging and maintenance. Especially for people with a safe and convenient operation. Instrument is installed in the high altitude, shall be made for the operating platform, ensure the safety of the people to be operated at high altitude. ( 3) 。 Flow sensor can be installed in horizontal, vertical or inclined pipes. But when measuring liquid, installed in vertical or inclined pipe flow sensor, must ensure that the flow of liquid from bottom to top, to ensure that the pipe full of liquid, and offset the impact of additional gravity. ( 4) 。 Upstream and downstream of flow sensor should have a long straight pipe, the size of the straight pipe and varies according to the upstream of the pipe type. ( 5) 。 Flow sensor installation of pipe diameter must be consistent with the flow sensor inside. Otherwise the flow sensor of the upstream and downstream piping installation to variable diameter. Choose pipe diameter of the principle is: the pipe diameter must be consistent with the nominal diameter of flow sensor. The relative error of two inner control in & plusmn; Less than 1%. In guarantee under the premise of compressive strength, nominal pressure in as far as possible big some. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.

are present in just about every facet of modern life.

To build customers value by delivering high-quality products, services and solutions in innovative and cost effective ways. Beijing Sincerity Automatic Equipment Co., Ltd will realize this mission by setting the highest standards in service, reliability, safety and cost containment in our industry.

Making a few technical tweaks to the way you structure and distribute mass flow meter could be the difference between an engaging, thought-provoking product and a perfunctory one.

The global market is estimated to reach a value of almost insertion ultrasonic flow meter in the next decade. have a robust position in the endress hauser ultrasonic flow meter market because of its proven high potency in rosemount coriolis mass flow meter.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect