loading

Sincerity Group | Coriolis flow meter manufacturers| 


Is there any time to pay attention to how to install the vortex flowmeter?

Abstract: How to install the vortex flowmeter? The information is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. Weinan and Shunda flowmeter manufacturers technical introduction The correct installation of the instrument is an important part of ensuring the normal operation of the instrument. If it is improperly installed, it will affect the accuracy of the instrument in light, and it will affect the service life of the instrument and even damage the instrument. Details below. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details on how to install the vortex flowmeter. The correct installation of the instrument is an important part of ensuring the normal operation of the instrument. If it is improperly installed, it will affect the accuracy of the instrument in light, and it will affect the service life of the instrument and even damage the instrument. The following is a detailed analysis of the matters needing attention when installing the vortex flowmeter. (1) Installation environment requirements: 1. Avoid strong electrical equipment, high frequency equipment, and strong switching power supply equipment as much as possible. The power supply for the instrument is separated from these devices as much as possible. 2. Avoid the direct influence of high temperature heat sources and radiation sources. If it must be installed, heat insulation and ventilation measures must be provided. 3. Avoid high humidity environment and strong corrosive gas environment. If it must be installed, there must be ventilation measures. 4. The vortex flow meter should be installed on pipelines with strong vibration as far as possible. If it must be installed, pipe fastening devices must be installed at 2D upstream and downstream, and anti-vibration pads must be added to enhance the anti-vibration effect. 5. The instrument is best installed indoors, and it should be waterproof when installed outdoors. Special attention should be paid to bending the cable into a U shape at the electrical interface to prevent water from entering the amplifier housing along the cable. 6. There should be ample space around the installation point of the instrument for wiring installation and regular maintenance. (2) Installation requirements of the instrument pipeline: 1. The vortex flow meter has certain requirements for the upstream and downstream straight pipe sections of the installation point, otherwise it will affect the flow field of the medium in the pipeline and affect the measurement accuracy of the instrument. Note: The regulating valve should not be installed upstream of the vortex flow meter as much as possible, but should be installed 10D downstream of the vortex flow meter. 2. The inner diameter of upstream and downstream piping should be the same. If there is a difference, the inner diameter Dp of the piping and the inner diameter Db of the vortex meter meter should satisfy the following relationship: 0.98Db≤Dp≤1.05Db The upstream and downstream piping should be concentric with the inner diameter of the flow meter, and the misalignment between them should be less than 0.05Db. 3. The gasket between the instrument and the flange should not protrude into the pipe during installation, and its inner diameter should be 1-2mm larger than the inner diameter of the meter. 4. Installation design of pressure measuring holes and temperature measuring holes. When the pipeline under test needs to be installed with temperature and pressure transmitters, the pressure measuring hole should be set at 3-5D downstream, and the temperature measuring hole should be set at 6-8D downstream. 5. The instrument can be installed horizontally, vertically or inclined on the pipeline. 6. When measuring gas, install the instrument in the vertical pipeline, and the gas flow direction is not limited. But if the pipe contains a small amount of liquid, in order to prevent the liquid from entering the measuring tube of the instrument, the air flow should flow from bottom to top. 7. When measuring liquid, in order to ensure that the pipe is filled with liquid, when installing the instrument in a vertical or inclined pipe, the direction of liquid flow should be from bottom to top. If the pipeline contains a small amount of gas, in order to prevent the gas from entering the measuring tube of the meter, the meter should be installed at the lower part of the pipeline. 8. When measuring high temperature and low temperature medium, attention should be paid to heat preservation measures. The high temperature inside the converter (in the case of the meter head) should generally not exceed 70℃; the low temperature will easily cause condensation inside the converter, reduce the insulation resistance of the printed circuit board, and affect the normal operation of the meter. Flowmeter manufacturers have been“Technology guarantees quality, innovation promotes development, and integrity weaves the future”, adhering to its own firm belief, and created a development path suitable for its own characteristics. Looking back, we firmly believe that,“factory”The future of our company is bound to be a sunny avenue full of flowers and smiling faces! The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our manufacturer. 'Is there any time to pay attention to how to install the vortex flowmeter?'

Beijing Sincerity Automatic Equipment Co., Ltd have now decided to extend our company in other countries.

Looking for a company to handle your mass flow meter tuning fork liquid density meter? Visit Sincerity Flow Meter today for more information.

We are making mass flow meter available to you at a very low price.

A technology team created for insuring that mass flow meter is produced with the finest materials and technologies.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect