Abstract: The introduction of the advantages of Changzhou Okay glass rotor flowmeter is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. The glass rotor flowmeter has the characteristics of pressure resistance, durability and accurate measurement. It can detect the flow rate of acid (except hydrofluoric acid), oxidant, alkali and other corrosive gases or liquids. It is suitable for pharmaceutical, chemical, sewage treatment and papermaking, etc. industry. glass rotor. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is an introduction to the advantages of Changzhou Okay glass rotor flowmeters. The glass rotor flowmeter has the characteristics of pressure resistance, durability and accurate measurement. It can detect the flow rate of acid (except hydrofluoric acid), oxidant, alkali and other corrosive gases or liquids. It is suitable for pharmaceutical, chemical, sewage treatment and papermaking, etc. industry. The glass rotor flowmeter is mainly composed of a conical glass tube that expands from bottom to top and a float that moves up and down with the flow rate of the fluid. The following will introduce the advantages of the glass rotor flowmeter produced by our company: 1. The straight pipe section requires a low glass rotameter because the flow field is stable and the pressure recovery speed is twice as fast as that of the orifice plate, which greatly shortens the requirements for the straight pipe section. Save a lot of straight pipe sections, especially special expensive material pipes. 2. Good repeatability and high linearity The product has the characteristics of symmetrical porous structure, which can balance the flow field, reduce the eddy current, signal and vibration noise, improve the stability of the flow field, and improve the linearity by 5-10% compared with the orifice plate. times, the repeatability is increased by 54% to 0.15%. From the perspective of its comprehensive performance, the balanced flowmeter belongs to the ranks of high-end flowmeters. Linearity up to 5:1 turndown ratio±Linearity up to 0.3% 7:1 turndown ratio±Linearity up to 0.5% of 10:1 turndown ratio±1.0% 3. Porous symmetrical balance design reduces pressure loss, reduces the formation of turbulent shear force and eddy current, reduces kinetic energy loss, and reduces 2.5 times compared with orifice plate under the same measurement conditions *Pressure loss, thus saving a considerable amount of operating energy costs, is an energy-saving instrument, worthy of a large number of promotion. 4. The long-term stability of the product is good. The direct friction between the medium and the throttling part is greatly reduced due to the obvious reduction of the turbulent shear force of the product.βThe value remains constant over a long period of time, and the entire meter has no moving parts, thus maintaining long-term stability. 5. Porous symmetrical balanced design that is resistant to dirt and not easy to block, reduces the formation of turbulent shear force and eddy current, thereby greatly reducing the formation of dead zone, ensuring the smooth passage of dirty media through multiple holes, reducing fluid holes Opportunity to be blocked. 6. Orifice plate glass rotameter can be replaced directly. It has the same usage and shape as the orifice plate, so it can be replaced directly without changing the related instruments and any piping changes. The plate is changed to a balanced flow meter. 7. Wide flow measurement range According to the test results, we know that the performance of the glass rotameter can make the flow rate from the minimum to the speed of sound, the minimum Reynolds number can be lower than 200, and the maximum Reynolds number is greater than 107.βThe value can be selected from 0.25 to 0.90. 8. Due to the special structural design of the product, the medium under complex working conditions can be measured, so that it has special performance. It can carry out gas-liquid two-phase, various low-temperature gases (such as LNG, liquid hydrogen, liquid oxygen, liquid argon, liquefied ethylene, liquefied petroleum gas, etc.), various mixed gases (such as gas, coal gas, biogas, etc.), gas-liquid Two-phase media (such as moisture), slurries, multi-phase water flow, vibrating water flow, electromagnetic interference media and bidirectional flow (because the balance flowmeter is completely symmetrical left and right). 9. The glass rotor flowmeter that can measure high temperature and high pressure media is the same as the throttling device such as the orifice plate. The working temperature and pressure depend on the material and grade of the pipes and flanges. The working temperature can reach 850 ℃ and the working pressure can reach 42MPa. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Introduction to the Advantages of Changzhou Okay Glass Rotameter Meters'
Beijing Sincerity Automatic Equipment Co., Ltd have expanded from facilitating conversation and collaboration in the identity industry to providing strategy consulting services, research, analytics and education.
Beijing Sincerity Automatic Equipment Co., Ltd seeks to lead the industry by instilling pride in our customers, creating value for the market and sharing responsibility around the world.
An easy and inexpensive mass flow meter solution can be easily obtained now through purchasing a mass flow meter rosemount coriolis mass flow meter online. Find your solution at Sincerity Flow Meter, your demand will be satified.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com